شعار
وطن

غرفة اختبار الموثوقية

غرفة اختبار الموثوقية

  • Basic troubleshooting methods for high and low temperature test chambers Basic troubleshooting methods for high and low temperature test chambers
    Oct 16, 2024
    Basic troubleshooting methods for high and low temperature test chambers: 1、 High and low temperature testing equipment. In high temperature testing, if the temperature change does not reach the test temperature value, the electrical system can be checked and the faults can be eliminated one by one. If the temperature rises slowly, you need to check the air circulation system to see if the regulating baffle of the air circulation is open normally. Otherwise, check the motor of the air circulation Is the operation normal. If the temperature overshoot is severe, it is necessary to adjust the PID setting parameters. If the temperature rises directly and is protected against overheating, the controller will malfunction and the control instrument must be replaced. 2、 When the high and low temperature test equipment suddenly malfunctions during the test operation, the corresponding fault display prompt and audible alarm prompt will appear on the control instrument. The operator can quickly identify which type of fault it belongs to by referring to the troubleshooting chapter in the operation and use of the equipment, and then ask professional personnel to quickly troubleshoot it to ensure the normal progress of the experiment. Other environmental testing equipment may experience other phenomena during use, so it is necessary to analyze and eliminate them specifically. Regular maintenance and upkeep of environmental testing equipment, regular cleaning of the condenser in the refrigeration system, lubrication of moving parts according to the instructions, and regular maintenance and inspection of the electrical control system are essential tasks 3、 If the low temperature of the high and low temperature testing instrument cannot meet the test indicators, then you need to observe the temperature changes, whether the temperature drops very slowly or there is a trend of temperature recovery after reaching a certain value. The former needs to check whether the working chamber is dried before conducting the low temperature test, so that the working chamber can be kept dry before putting the test sample into the working chamber for further testing. If there are too many test samples placed in the working chamber, which prevent the air in the working chamber from fully circulating, after ruling out the above reasons, you need to consider whether it is a fault in the refrigeration system. In this case, you need to hire professional personnel from the Lab Companion manufacturer for maintenance. The latter phenomenon is caused by poor usage environment of the equipment. The temperature and location of the equipment placement (distance between the box and the wall) must meet the requirements (as specified in the equipment operation instructions). At present, the company's main products include: high and low temperature test chambers, rapid temperature change test chambers, constant temperature and humidity test chambers, and high and low temperature impact test chambers.
    إقرأ المزيد
  • User selection environment test box must read User selection environment test box must read
    Oct 15, 2024
    User selection environment test box must read 1、 Equipment selection criteria There is currently no exact number of natural environmental factors and induced environmental factors that exist on the surface of the Earth and in the atmosphere, among which there are no less than a dozen factors that have a significant impact on the use and lifespan of engineering products (equipment). Engineers engaged in the study of environmental conditions for engineering products have compiled and summarized the environmental conditions that exist in nature and are induced by human activities into a series of testing standards and specifications to guide the environmental and reliability testing of engineering products. For example, GJB150- the National Military Standard of the People's Republic of China for Environmental Testing of Military Equipment, and GB2423- the National Standard of the People's Republic of China for Environmental Testing of Electrical and Electronic Products, which guides environmental testing of electrical and electronic products. Therefore, the main basis for selecting environmental and reliability testing equipment is the testing specifications and standards of engineering products. Secondly, in order to standardize the tolerance of environmental testing conditions in experimental equipment and ensure the control accuracy of environmental parameters, national technical supervision agencies and various industrial departments have also formulated a series of calibration regulations for environmental testing equipment and detection instruments. Such as the national standard GB5170 of the People's Republic of China "Basic Parameter Calibration Method for Environmental Testing Equipment of Electrical and Electronic Products", and JJG190-89 "Trial Calibration Regulations for Electric Vibration Test Stand System" issued and implemented by the State Administration of Technical Supervision. These verification regulations are also an important basis for selecting environmental and reliability testing equipment. Testing equipment that does not meet the requirements of these verification regulations is not allowed to be put into use. 2、 Basic principles for equipment selection The selection of environmental and reliability testing equipment should follow the following five basic principles: 1. Reproducibility of environmental conditions It is impossible to fully and accurately reproduce the environmental conditions that exist in nature in the laboratory. However, within a certain tolerance range, people can accurately and approximately simulate the external environmental conditions that engineering products undergo during use, storage, transportation, and other processes. This passage can be summarized in engineering language as follows: "The environmental conditions (including platform environment) created by the testing equipment around the tested product should meet the requirements of the environmental conditions and their tolerances specified in the product testing specifications. The temperature box used for military product testing should not only meet the requirements of the national military standards GJB150.3-86 and GJB150.4-86 for different uniformity and temperature control accuracy. Only in this way can the reproducibility of environmental conditions be ensured in environmental testing. 2. Repeatability of environmental conditions An environmental testing equipment may be used for multiple tests of the same type of product, and a tested engineering product may also be tested in different environmental testing equipment. In order to ensure the comparability of test results obtained for the same product under the same environmental testing conditions specified in the testing specifications, it is necessary to require the environmental conditions provided by the environmental testing equipment to be reproducible. This means that the stress levels (such as thermal stress, vibration stress, electrical stress, etc.) applied by environmental testing equipment to the tested product are consistent with the requirements of the same testing specification. The repeatability of environmental conditions provided by environmental testing equipment is guaranteed by the national metrological verification department after passing the verification according to the verification regulations formulated by the national technical supervision agency. Therefore, it is necessary to require environmental testing equipment to meet the requirements of various technical indicators and accuracy indicators in the calibration regulations, and to not exceed the time limit specified in the calibration cycle in terms of usage time. If a very common electric vibration table is used, in addition to meeting technical indicators such as excitation force, frequency range, and load capacity, it must also meet the requirements of precision indicators such as lateral vibration ratio, table acceleration uniformity, and harmonic distortion specified in the calibration regulations. Moreover, the service life after each calibration is two years, and after two years, it must be re calibrated and qualified before being put into use. 3. Measurability of environmental condition parameters The environmental conditions provided by any environmental testing equipment must be observable and controllable. This is not only to limit the environmental parameters within a certain tolerance range and ensure the reproducibility and repeatability of the test conditions, but also necessary for the safety of product testing, in order to prevent damage to the tested product caused by uncontrolled environmental conditions and unnecessary losses. At present, various experimental standards generally require that the accuracy of parameter testing should not be less than one-third of the allowable error under experimental conditions. 4. Exclusion of environmental testing conditions Every time an environmental or reliability test is conducted, there are strict regulations on the category, magnitude, and tolerance of environmental factors, and non test required environmental factors are excluded from penetrating into it, in order to provide a definite basis for judging and analyzing product failure and fault modes during or after the test. Therefore, it is required that environmental testing equipment not only provide the specified environmental conditions, but also not allow any other environmental stress interference to be added to the tested product. As defined in the verification regulations for electric vibration tables, the table leakage magnetic flux, acceleration signal-to-noise ratio, and total root mean square value ratio of in band and out of band acceleration. The accuracy indicators such as random signal verification and harmonic distortion are all established as verification items to ensure the uniqueness of environmental testing conditions. 5. Safety and reliability of experimental equipment Environmental testing, especially reliability testing, has a long testing cycle and sometimes targets high-value military products. During the testing process, testing personnel often need to operate, inspect or test around the site. Therefore, it is required that environmental testing equipment must have the characteristics of safe operation, convenient operation, reliable use, and long working life to ensure the normal progress of the testing itself. The various protection, alarm measures, and safety interlock devices of the testing equipment should be complete and reliable to ensure the safety and reliability of the testing personnel, the tested products, and the testing equipment itself. 3、 Selection of Temperature and Humidity Chamber 1. Selection of Capacity When placing the test product (components, assemblies, parts or whole machine) into a climate chamber for testing, in order to ensure that the atmosphere around the test product can meet the environmental testing conditions specified in the test specifications, the working dimensions of the climate chamber and the overall dimensions of the test product should follow the following regulations: a) The volume of the tested product (W × D × H) shall not exceed (20-35)% of the effective working space of the test chamber (20% is recommended). For products that generate heat during testing, it is recommended to use no more than 10%. b) The ratio of the windward cross-sectional area of the tested product to the total area of the test chamber on that section shall not exceed (35-50)% (35% is recommended). c) The distance between the outer surface of the tested product and the wall of the test chamber should be kept at least 100-150mm (recommended 150mm). The above three provisions are actually interdependent and unified. Taking a 1 cubic meter cube box as an example, an area ratio of 1: (0.35-0.5) is equivalent to a volume ratio of 1: (0.207-0.354). A distance of 100-150mm from the box wall is equivalent to a volume ratio of 1: (0.343-0.512). In summary, the working chamber volume of the climate environment test chamber should be at least 3-5 times the external volume of the tested product. The reasons for making such regulations are as follows: After the test piece is placed in the box, it occupies the smooth channel, and narrowing the channel will lead to an increase in airflow velocity. Accelerate the heat exchange between the airflow and the test piece. This is inconsistent with the reproduction of environmental conditions, as relevant standards stipulate that the air flow velocity around the test specimen in the test chamber should not exceed 1.7m/s for temperature environmental tests, in order to prevent the test specimen and the surrounding atmosphere from generating heat conduction that is not in line with reality. When unloaded, the average wind speed inside the test chamber is 0.6-0.8m/s, not exceeding 1m/s. When the space and area ratio specified in points a) and b) are met, the wind speed in the flow field may increase by (50-100)%, with an average maximum wind speed of (1-1.7) m/s. Meet the requirements specified in the standards. If the volume or windward cross-sectional area of the test piece is increased without restrictions during the experiment, the actual airflow speed during the test will exceed the maximum wind speed specified in the test standard, and the validity of the test results will be questioned. The accuracy indicators of environmental parameters in the working chamber of the climate chamber, such as temperature, humidity, salt spray settling rate, etc., are all measured under no-load conditions. Once the test piece is placed, it will have an impact on the uniformity of the environmental parameters in the working chamber of the test chamber. The larger the space occupied by the test piece, the more severe this impact will be. Experimental data shows that the temperature difference between the windward and leeward sides in the flow field can reach 3-8 ℃, and in severe cases, it can be as high as 10 ℃ or more. Therefore, it is necessary to meet the requirements of a] and b] as much as possible to ensure the uniformity of environmental parameters around the tested product. According to the principle of heat conduction, the temperature of the airflow near the box wall is usually 2-3 ℃ different from the temperature at the center of the flow field, and may even reach 5 ℃ at the upper and lower limits of high and low temperatures. The temperature of the box wall differs from the temperature of the flow field near the box wall by 2-3 ℃ (depending on the structure and material of the box wall). The greater the difference between the test temperature and the external atmospheric environment, the greater the temperature difference. Therefore, the space within a distance of 100-150mm from the box wall is unusable. 2. Selection of temperature range At present, the range of temperature test chambers abroad is generally -73 to+177 ℃, or -70 to+180 ℃. Most domestic manufacturers generally operate at -80 to+130 ℃, -60 to+130 ℃, -40 to+130 ℃, and there are also high temperatures up to 150 ℃. These temperature ranges can usually meet the temperature testing needs of the vast majority of military and civilian products in China. Unless there are special requirements, such as products installed near heat sources such as engines, the upper temperature limit should not be blindly increased. Because the higher the upper limit temperature, the greater the temperature difference between the inside and outside of the box, and the poorer the uniformity of the flow field inside the box. The smaller the available studio size. On the other hand, the higher the upper limit temperature value, the higher the heat resistance requirements for insulation materials (such as glass wool) in the interlayer of the box wall. The higher the requirement for the sealing of the box, the higher the production cost of the box. 3. Selection of humidity range The humidity indicators given by domestic and foreign environmental test chambers are mostly 20-98% RH or 30-98% RH. If the humid heat test chamber does not have a dehumidification system, the humidity range is 60-98%. This type of test chamber can only perform high humidity tests, but its price is much lower. It is worth noting that the corresponding temperature range or minimum dew point temperature should be indicated after the humidity index. Because relative humidity is directly related to temperature, for the same absolute humidity, the higher the temperature, the lower the relative humidity. For example, if the absolute humidity is 5g/Kg (referring to 5g of water vapor in 1kg of dry air), when the temperature is 29 ℃, the relative humidity is 20% RH, and when the temperature is 6 ℃, the relative humidity is 90% RH. When the temperature drops below 4 ℃ and the relative humidity exceeds 100%, condensation will occur inside the box. To achieve high temperature and high humidity, simply spray steam or atomized water droplets into the air of the box for humidification. Low temperature and humidity are relatively difficult to control because the absolute humidity at this time is very low, sometimes much lower than the absolute humidity in the atmosphere. It is necessary to dehumidify the air flowing inside the box to make it dry. At present, the vast majority of temperature and humidity chambers both domestically and internationally adopt the principle of refrigeration and dehumidification, which involves adding a set of refrigeration light pipes to the air conditioning room of the chamber. When humid air passes through a cold pipe, its relative humidity will reach 100% RH, as the air saturates and condenses on the light pipe, making the air drier. This dehumidification method theoretically can reach dew point temperatures below zero degrees, but when the surface temperature of the cold spot reaches 0 ℃, the water droplets condensed on the surface of the light pipe will freeze, affecting the heat exchange on the surface of the light pipe and reducing the dehumidification capacity. Also, because the box cannot be completely sealed, humid air from the atmosphere will seep into the box, causing the dew point temperature to rise. On the other hand, the moist air flowing between the light tubes only reaches saturation at the moment of contact with the light tubes (cold spots) and releases water vapor, so this dehumidification method is difficult to keep the dew point temperature inside the box below 0 ℃. The actual minimum dew point temperature achieved is 5-7 ℃. A dew point temperature of 5 ℃ is equivalent to an absolute moisture content of 0.0055g/Kg, corresponding to a relative humidity of 20% RH at a temperature of 30 ℃. If a temperature of 20 ℃ and a relative humidity of 20% RH are required, with a dew point temperature of -3 ℃, it is difficult to use refrigeration for dehumidification, and an air drying system must be selected to achieve it. 4. Selection of control mode There are two types of temperature and humidity test chambers: constant test chamber and alternating test chamber. The ordinary high and low temperature test chamber generally refers to a constant high and low temperature test chamber, which is controlled by setting a target temperature and has the ability to automatically maintain a constant temperature to the target temperature point. The control method of the constant temperature and humidity test chamber is also similar, setting a target temperature and humidity point, and the test chamber has the ability to automatically maintain a constant temperature to the target temperature and humidity point. The high and low temperature alternating test chamber has one or more programs for setting high and low temperature changes and cycles. The test chamber has the ability to complete the test process according to the preset curve, and can accurately control the heating and cooling rates within the maximum heating and cooling rate capability range, that is, the heating and cooling rates can be controlled according to the slope of the set curve. Similarly, the high and low temperature alternating humidity test chamber also has preset temperature and humidity curves, and the ability to control them according to the preset. Of course, alternating test chambers have the function of constant test chambers, but the manufacturing cost of alternating test chambers is relatively high because they need to be equipped with curve automatic recording devices, program controllers, and solve problems such as turning on the refrigeration machine when the temperature in the working room is high. Therefore, the price of alternating test chambers is generally more than 20% higher than that of constant test chambers. Therefore, we should take the need for experimental methods as the starting point and choose a constant test chamber or an alternating test chamber. 5. Selection of variable temperature rate Ordinary high and low temperature test chambers do not have a cooling rate indicator, and the time from the ambient temperature to the nominal lowest temperature is generally 90-120 minutes. The high and low temperature alternating test chamber, as well as the high and low temperature alternating wet heat test chamber, both have temperature change speed requirements. The temperature change speed is generally required to be 1 ℃/min, and the speed can be adjusted within this speed range. The rapid temperature change test chamber has a fast temperature change rate, with heating and cooling rates ranging from 3 ℃/min to 15 ℃/min. In certain temperature ranges, the heating and cooling rates can even reach over 30 ℃/min. The temperature range of various specifications and speeds of rapid temperature change test chambers is generally the same, that is, -60 to+130 ℃. However, the temperature range for assessing the cooling rate is not the same. According to different test requirements, the temperature range of rapid temperature change test chambers is -55 to+80 ℃, while others are -40 to+80 ℃. There are two methods for determining the temperature change rate of the rapid temperature change test chamber: one is the average temperature rise and fall rate throughout the entire process, and the other is the linear temperature rise and fall rate (actually the average speed every 5 minutes). The average speed throughout the entire process refers to the ratio of the difference between the highest and lowest temperatures within the temperature range of the test chamber to the time. At present, the technical parameters of temperature change rate provided by various environmental testing equipment manufacturers abroad refer to the average rate throughout the entire process. The linear temperature rise and fall rate refers to the guaranteed temperature change rate within any 5-minute time period. In fact, for the rapid temperature change test chamber, the most difficult and critical stage to ensure the linear temperature rise and fall speed is the cooling rate that the test chamber can achieve during the last 5 minutes of the cooling period. From a certain perspective, the linear heating and cooling speed (average speed every 5 minutes) is more scientific. Therefore, it is best for the experimental equipment to have two parameters: the average temperature rise and fall speed throughout the entire process and the linear temperature rise and fall speed (average speed every 5 minutes). Generally speaking, the linear heating and cooling speed (average speed every 5 minutes) is half of the average heating and cooling speed throughout the entire process. 6. Wind speed According to relevant standards, the wind speed inside the temperature and humidity chamber during environmental testing should be less than 1.7m/s. For the test itself, the lower the wind speed, the better. If the wind speed is too high, it will accelerate the heat exchange between the surface of the test piece and the airflow inside the chamber, which is not conducive to the authenticity of the test. But in order to ensure uniformity within the testing chamber, it is necessary to have circulating air inside the testing chamber. However, for rapid temperature change test chambers and comprehensive environmental test chambers with multiple factors such as temperature, humidity, and vibration, in order to pursue the rate of temperature change, it is necessary to accelerate the flow velocity of the circulating airflow inside the chamber, usually at a speed of 2-3m/s. Therefore, the wind speed limit varies for different usage purposes. 7. Temperature fluctuation Temperature fluctuation is a relatively easy parameter to implement, and most test chambers produced by environmental testing equipment manufacturers can actually control temperature fluctuations within a range of ± 0.3 ℃. 8. Uniformity of temperature field In order to simulate the actual environmental conditions that products experience in nature more accurately, it is necessary to ensure that the surrounding area of the tested product is under the same temperature environment conditions during environmental testing. Therefore, it is necessary to limit the temperature gradient and temperature fluctuation inside the test chamber. In the General Principles of Environmental Test Methods for Military Equipment (GJB150.1-86) of the National Military Standard, it is clearly stipulated that "the temperature of the measurement system near the test sample should be within ± 2 ℃ of the test temperature, and its temperature should not exceed 1 ℃/m or the total maximum value should be 2.2 ℃ (when the test sample is not working). 9. Precision control of humidity The humidity measurement in the environmental testing chamber mostly adopts the dry wet bulb method. The manufacturing standard GB10586 for environmental testing equipment requires that the relative humidity deviation should be within ± 23% RH. To meet the requirements of humidity control accuracy, the temperature control accuracy of the humidity test chamber is relatively high, and the temperature fluctuation is generally less than ± 0.2 ℃. Otherwise, it will be difficult to meet the requirements for humidity control accuracy. 10. Cooling method selection If the test chamber is equipped with a refrigeration system, the refrigeration system needs to be cooled. There are two forms of test chambers: air-cooled and water-cooled.   Forced air cooling     Water-cooling Working conditions The equipment is easy to install, only need to power on. The ambient temperature should be lower than 28℃. If the ambient temperature is higher than 28℃, it has a certain impact on the refrigeration effect (preferably with air conditioning), the circulating cooling water system should be configured. Heat exchange effect  Poor (relative to the water-cooling mode)  Stable, good  Noise Large (relative to the water-cooling mode)    Less
    إقرأ المزيد
  • The walk-in high and low temperature (humid and hot) laboratory also needs maintenance The walk-in high and low temperature (humid and hot) laboratory also needs maintenance
    Oct 15, 2024
    The walk-in high and low temperature (humid and hot) laboratory also needs maintenance Reminder: Remember to maintain the walk-in high and low temperature (humid and hot) laboratory as well! 1. The temperature and humidity testing system of the walk-in high and low temperature (humid and hot) laboratory must be operated and maintained by a dedicated person. Strictly follow the operating procedures of the system and avoid others from operating the system illegally. 2. Long term shutdown of the walk-in high and low temperature (humid and hot) laboratory can affect the effective service life of the system. Therefore, the system should be turned on and operated at least once every 10 days; Do not repeatedly stop the system in a short period of time. The number of starts per hour should be less than 5 times, and the time interval between each start stop should not be less than 3 times; Do not open the door of the walk-in temperature and humidity testing system at low temperatures to prevent damage to the door sealing tape. 3. A system usage file should be established to facilitate system maintenance and repair. The use of archives should record the start and end time (date) of each system operation, the type of experiment, and the ambient temperature; When the system malfunctions, provide a detailed description of the fault phenomenon as much as possible; The maintenance and repair of the system should also be recorded in as much detail as possible. 4. Conduct a monthly main power switch (leakage circuit breaker) operation test to ensure that the switch is used as a leakage protector while meeting the load capacity. The specific steps are as follows: first, please confirm that the main power switch is turned to "ON", which means the system is powered on, and then press the test button. If the switch lever of the residual current circuit breaker falls down, this function is normal. 5. The main box of the walk-in temperature and humidity testing system should be protected during use and should not be subjected to strong impacts from sharp or blunt objects. 6. To ensure the normal and clean supply of cooling water, the cooling water filter of the refrigeration unit should be cleaned every 30 days. If the local air quality is poor and the dust content in the air is high, the cooling water tower reservoir should generally be cleaned every 7 days. 7. The leakage, overload, and short-circuit protection characteristics of the residual current switch are set by Lab Companion manufacturer and cannot be adjusted arbitrarily during use to avoid affecting performance; After the leakage switch is disconnected due to a short circuit, the contacts need to be checked. If the main contacts are severely burned or have pits, maintenance is required. 8. The test products placed in the walk-in temperature and humidity testing system should be kept at a certain distance from the suction and exhaust ports of the air conditioning channel to avoid obstructing air circulation. 9. Overtemperature protector action test. Set the temperature of the over temperature protector to be lower than the temperature of the box. If there is an E0.0 alarm and buzzing sound, it indicates that its function is normal. After completing the above experiment, the temperature protection setting should be reset appropriately, otherwise it may cause inappropriate termination. 10. Once a year, use a vacuum cleaner to clean and remove dust from the distribution room and water circuit room. Once a month, use a dry cloth to clean the accumulated water in the water tray of the refrigeration unit.
    إقرأ المزيد
  • Maintenance of refrigeration compressor for constant temperature and humidity test chamber, cold and hot shock test chamber Maintenance of refrigeration compressor for constant temperature and humidity test chamber, cold and hot shock test chamber
    Oct 14, 2024
    Maintenance of refrigeration compressor for constant temperature and humidity test chamber, cold and hot shock test chamber Article summary: For environmental monitoring equipment, the only way to maintain long-term and stable use is to pay attention to maintenance in all aspects. Here, we will introduce the maintenance of the compressor, which is an important component of the constant temperature and humidity test chamber and the cold and hot shock test chamber Detailed content: Maintenance plan for refrigeration compressor: As the core component of the refrigeration system in the constant temperature and humidity test chamber, the maintenance of the compressor is essential. Guangdong Hongzhan Technology Co., Ltd. introduces the daily maintenance steps and precautions for the compressor in the constant temperature and humidity test chamber and the cold and hot shock test chamber 1、 Carefully check the sound of the cylinders and moving parts at all levels to determine if their working condition is normal. If any abnormal sound is found, immediately stop the machine for inspection; 2、 Pay attention to whether the indicated values of pressure gauges at all levels, pressure gauges on gas storage tanks and coolers, and lubricating oil pressure gauges are within the specified range; 3、 Check if the temperature and flow rate of the cooling water are normal; 4、 Check the supply of lubricating oil and the lubrication system of the moving mechanism (some compressors are equipped with organic glass baffles on the side of the cross head guide rail of the machine body), You can directly see the movement of the crosshead and the supply of lubricating oil; The cylinder and packing can be inspected for oil discharge using a one-way valve, which can check if the oil injector is inserted into the cylinder Oil injection situation; 5、 Observe whether the oil level in the body oil tank and the lubricating oil in the oil injector are below the scale line. If they are low, they should be refilled in a timely manner (if using a dipstick, stop and check); 6、 Check the temperature of the intake and exhaust valve covers at the cross guide rail of the crankcase with your hand to see if it is normal; 7、 Pay attention to the temperature rise of the motor, bearing temperature, and whether the readings on the voltmeter and ammeter are normal. The current should not exceed the rated current of the motor. If it exceeds the rated current, the cause should be identified or the machine should be stopped for inspection; 8、 Regularly check whether there are any debris or conductive objects inside the motor, whether the coil is damaged, and whether there is friction between the stator and rotor, otherwise the motor will burn out after starting; 9、 If it is a water-cooled compressor and water cannot be immediately supplied after the water is cut off, it is necessary to avoid cylinder cracking due to uneven heating and cooling. After parking in winter, the cooling water should be drained to prevent freezing and cracking of the cylinder and other parts; 10、 Check whether the compressor vibrates and whether the foundation screws are loose or detached; 11、 Check whether the pressure regulator or load regulator, safety valve, etc. are sensitive; 12、 Pay attention to the hygiene of the compressor, its associated equipment, and the environment; 13、 Gas storage tanks, coolers, and oil-water separators should regularly release oil and water; 14、 The lubricating machine used should be filtered by sedimentation. Differentiate the use of compressor oil between winter and summer
    إقرأ المزيد
  • EC-85EXT ، حمام درجة حرارة ثابتة متفوقة (800 لتر) المواصفات الفنية EC-85EXT ، حمام درجة حرارة ثابتة متفوقة (800 لتر) المواصفات الفنية
    Nov 13, 2014
    EC-85EXT، مواصفات حوض استحمام بدرجة حرارة ثابتة فائقة (800 لتر).مشروعيكتبمسلسلEXTوظيفةتحدث درجة الحرارة بطريقة ماطريقة الكرة الجافةمروحة درجة الحرارة يين-70 ~ + 150 درجة مئويةسعة الإباضة في درجة الحرارةأقل من +100 درجة مئوية± 0.3 درجة مئويةفوق +101 درجة مئوية± 0.5 درجة مئويةتوزيع درجة الحرارةأقل من +100 درجة مئوية± 0.7 درجة مئويةفوق +101 درجة مئوية± 1.0 درجة مئويةتنخفض درجة الحرارة الوقت+125 ~-55 درجة مئويةفي غضون 36 دقيقة (10 درجة مئوية / دقيقة متوسط تغير درجة الحرارة)وقت ارتفاع درجة الحرارة-55 ~+125 درجه مئويةفي غضون 36 دقيقة (10 درجة مئوية / دقيقة متوسط تغير درجة الحرارة)تم اختبار الحجم الداخلي للرحم800Lطريقة قياس بوصة الغرفة (العرض والعمق والارتفاع)1000 مم × 800 مم × 1000 ممطريقة بوصة المنتج (العرض والعمق والارتفاع)1470 مم × 2240 مم × 2000 مماصنع المادة الزي الخارجي لوحة تحكم غرفة الاختبارغرفة الآلةلوحة الصلب المتداخلة الباردة رمادية داكنةداخللوح من الفولاذ المقاوم للصدأ (SUS304,2B مصقول)مادة حرارية مكسورةاختبار الرحمراتنجات صناعية صلبةالصوف الزجاجيبابقطن رغوي من الراتنج الصناعي الصلب، قطن زجاجيمشروعيكتبمسلسلEXTجهاز التبريد والرطوبة طريقة التبريدوضع الانكماش والتجميد الميكانيكي ووضع التجميد الثنائي وسط التبريدجانب قطعة واحدةR404Aثنائي درجة الحرارة المرتفعة / جانب درجة الحرارة المنخفضةR404A + R23التبريد ومزيل الرطوبةنوع المشتت الحراري المختلط متعدد القنواتالمكثف(المياه المبردة)مسعراستمارةسخان سبائك النيكل والكروم المقاوم للحرارةمنفاخاستمارةتحريك المروحة المراقب الماليتم ضبط درجة الحرارة-72.0 ~ +152.0 درجة مئويةضبط الوقت فاني0 ~ 999 الوقت 59 دقيقة (نوع مبرمج)0 ~ 20000 الوقت 59 دقيقة (القيمة)ضبط طاقة التحلل درجة الحرارة 0.1 درجة مئوية، الوقت دقيقة واحدةتشير إلى الدقةدرجة الحرارة ± 0.8 درجة مئوية (النوع)، الوقت ± 100 جزء في المليوننوع الإجازةالقيمة أو البرنامجرقم المرحلة20 مرحلة / 1 برنامجعدد الإجراءاتالحد الأقصى لعدد برامج القوة الواردة (RAM) هو 32 برنامجًاالحد الأقصى لعدد برامج ROM الداخلية هو 13 برنامجًارقم الرحلة ذهابا وإياباالحد الأقصى 98 أو غير محدودعدد مرات تكرار الرحلة ذهابًا وإيابًاالحد الأقصى 3 مراتإزاحة النهايةحزب العمال 100Ω (عند 0 ℃)، الصف ( JIS C 1604-1997 )إجراء التحكمعند تقسيم الإجراء PIDوظيفة الفيروس الداخليوظيفة التسليم المبكر، وظيفة الاستعداد، تحديد وظيفة صيانة القيمة، وظيفة حماية انقطاع التيار الكهربائي،وظيفة اختيار عمل الطاقة، وظيفة الصيانة، وظيفة النقل ذهابًا وإيابًا،وظيفة تسليم الوقت، وظيفة إخراج إشارة الوقت، وظيفة منع الإفراط في التبريد الزائد،وظيفة التمثيل غير الطبيعي، وظيفة إخراج التنبيه الخارجي، إعداد وظيفة تمثيل النموذج،وظيفة اختيار نوع النقل، يمثل وقت الحساب الوظيفة، وظيفة مصباح الفتحةمشروعيكتبمسلسلEXTلوحة التحكمآلة المعداتلوحة التشغيل LCD (اكتب لوحة الاتصال)،يمثل المصباح (الطاقة، النقل، غير الطبيعي)، محطة إمداد الطاقة الاختبارية، محطة الإنذار الخارجية،محطة إخراج إشارة الوقت، موصل سلك الطاقة جهاز الحمايةدورة التبريدجهاز حماية الزائد، جهاز حجب عاليةمسعرجهاز حماية من ارتفاع درجة الحرارة، مصهر درجة الحرارةمنفاخجهاز حماية الزائدلوحة التحكمقاطع التسرب لإمدادات الطاقة، المصهر (السخان،)،المصهر (لحلقة التشغيل)، جهاز الحماية من ارتفاع درجة الحرارة (للاختبار)،جهاز منع التبريد الزائد لارتفاع درجة الحرارة (مادة الاختبار، في الحواسيب الصغيرة)الدفع ينتمي إلى المنتجتم تسليط مواد الاختبار بواسطة * 8سقيفة من الفولاذ المقاوم للصدأ (2)، سقيفة استقبال (4)الصماماتصمامات حماية حلقة التشغيل (2)مواصفات التشغيل(1) آخربولس (فتحة الكابل: 1)منتجات المعداتالبرانيةزجاج البورسليكات الصلب 270 مم × 190 مم1 فتحة الكابلحجم الحفرة 50 ملم1 الحوض الصغير داخل المصباحكرة ساخنة بيضاء AC100V 15W1 عجلة 6 التعديل الأفقي 6 خصائص الفيروس الكهربائيالمصدر *5.1التيار المتردد  ثلاث مراحل  380 فولت  50 هرتزالحد الأقصى للحمل الحالي60 أقدرة قاطع التسرب لإمدادات الطاقة80 أالتيار الحسي  30 مللي أمبيرسمك توزيع الطاقة60 ملم2خرطوم عازل مطاطيخشونة سلك التأريض14 ملم2 مياه التبريد * 5.3محصول الماء5000 لتر / ساعة (عندما تكون درجة حرارة مدخل ماء التبريد 32 درجة مئوية)ضغط الماء0.1 ~ 0.5 ميجا باسكالقطر الأنبوب الجانبي للجهازPT1 1/4 الأنابيب أنبوب التصريف  * 5.4بي تي1/2وزن المنتج700 كجم 
    إقرأ المزيد
  • مربع اختبار شامل مربع اختبار شامل
    Oct 10, 2024
    صندوق اختبار شاملميزات المعدات:يمكن توصيلها بطاولة اهتزاز رأسية أو بطاولات اهتزاز رأسية وأفقية في وقت واحد؛يمكنك اختيار وظائف مثل رفع الجهاز وترجمة الجهاز؛تصميم هيكلي عالي القوة والموثوقية - يضمن الموثوقية العالية للمعدات؛مادة الاستوديو مصنوعة من الفولاذ المقاوم للصدأ SUS304 - مع مقاومة قوية للتآكل، ووظيفة التعب البارد والساخن، وعمر خدمة طويل؛مادة عازلة من رغوة البولي يوريثان عالية الكثافة - تضمن الحد الأدنى من فقدان الحرارة؛معالجة الرش السطحي - ضمان وظيفة مقاومة التآكل طويلة الأمد وعمر المظهر للمعدات؛شريط ختم مطاط السيليكون المقاوم للحرارة عالي القوة - يضمن أداء إغلاق عالي لأبواب المعدات؛وظائف اختيارية متعددة (مثل فتحات الاختبار، والمسجلات، وأنظمة تنقية المياه، وما إلى ذلك) تضمن أن لدى المستخدمين وظائف واحتياجات اختبار متعددة؛نافذة مراقبة كهربائية كبيرة مضادة للصقيع وإضاءة مخفية - يمكن أن توفر تأثير مراقبة جيد؛المبردات الصديقة للبيئة - تأكد من أن المعدات تلبي متطلبات حماية البيئة الخاصة بك بشكل أفضل؛حجم قابل للتخصيص/مؤشرات الاستخدام/وظائف اختيارية مختلفة وفقًا لمتطلبات المستخدمالتحكم في درجة الحرارةيمكن تحقيق التحكم المستمر في درجة الحرارة والتحكم في البرنامج؛يمكن لمسجل بيانات العملية الكاملة (وظيفة اختيارية) تحقيق تسجيل العملية الكاملة وإمكانية تتبع العملية التجريبية؛تم تجهيز كل محرك بحماية من التيار الزائد (ارتفاع درجة الحرارة) / حماية ماس كهربائى للسخان لضمان موثوقية عالية لتدفق الهواء والتدفئة أثناء تشغيل المعدات؛تعمل واجهة USB ووظيفة اتصال Ethernet على تمكين وظائف الاتصال وتوسيع البرامج بالجهاز لتلبية احتياجات العملاء المختلفة؛من خلال اعتماد وضع التحكم في التبريد المشهور عالميًا، يمكن تعديل قوة تبريد الضاغط تلقائيًا من 0% إلى 100%، مما يقلل من استهلاك الطاقة بنسبة 30% مقارنة بوضع التحكم في درجة حرارة توازن التسخين التقليدي؛المكونات الرئيسية للتبريد والتحكم الكهربائي كلها مصنوعة من منتجات ذات علامات تجارية مشهورة عالميًا، مما يحسن ويضمن الجودة الشاملة للمعدات؛المعدات تلبي المعايير التاليةGB/T 10592-2008 الشروط الفنية لـ غرف اختبار درجات الحرارة العالية والمنخفضةGB/T 10586-2006 الشروط الفنية لغرفة اختبار الحرارة الرطبةGB/T 2423.1-2008 الاختبار البيئي للمنتجات الكهربائية والإلكترونية - الجزء 2: طرق الاختبار - الاختبار أ: درجة الحرارة المنخفضةGB/T 2423.2-2008 الاختبار البيئي للمنتجات الكهربائية والإلكترونية - الجزء 2: طرق الاختبار - الاختبار ب: درجة الحرارة العاليةGB/T 2423.3-2006 الاختبار البيئي للمنتجات الكهربائية والإلكترونية - الجزء 2: طرق الاختبار - كابينة الاختبار: اختبار الحرارة الرطبة الثابتةGB/T 2423.4-2008 الاختبار البيئي للمنتجات الكهربائية والإلكترونية - الجزء 2: طرق الاختبار - قاعدة بيانات الاختبار: الحرارة الرطبة المتناوبة (دورة 12 ساعة + 12 ساعة)GB/T 2423.22-2008 الاختبار البيئي للمنتجات الكهربائية والإلكترونية - الجزء 2: طرق الاختبار - الاختبار N: التغيرات في درجات الحرارةGB/T 5170.1-2008 المبادئ العامة لطرق فحص معدات الاختبار البيئي للمنتجات الكهربائية والإلكترونيةGJB 150.3A-2009 طرق الاختبار البيئي لمختبر المعدات العسكرية الجزء 3: اختبار درجة الحرارة العاليةGJB 150.4A-2009 طرق الاختبار البيئي لمختبر المعدات العسكرية الجزء 4: اختبار درجة الحرارة المنخفضةGJB 150.9A-2009 طرق الاختبار البيئي لمختبر المعدات العسكرية الجزء 9: اختبار الحرارة الرطبةيمكن أن يؤدي اختيار أجسام طاولة الاهتزاز المختلفة إلى تلبية طرق اختبار الاهتزاز القياسية المختلفة(على سبيل المثال، GB/T 2423.35-2005، GB/T 2423.36-2005، وما إلى ذلك).ثلاث غرف اختبار شاملة؛ درجة الحرارة والرطوبة والاهتزاز ثلاث غرف اختبار شاملة؛ المواصفات الفنية لدرجة الحرارة/الرطوبة/الاهتزاز/ثلاثة أجهزة اختبار شاملة.نموذجثف-500ثف-1000ثف-1500البعد الداخليD7009001250W80011501150H90011001100حجم توصيل طاولة الاهتزاز (مم)الحامل الأفقي ≥400*400 المنصة العمودية ≥Φ400الحامل الأفقي ≥600*600 منصة عمودية ≥Φ600 منصة عمودية مفردة ≥Φ630mmالحامل الأفقي ≥900*900 المنصة العمودية ≥Φ900ارتفاع غطاء المحرك (مم)235مصدرنظام AC380V.50HZ ثلاثي الطور رباعي الأسلاك + سلك التأريضالتخطيط القياسيدليل منتج واحد، تقرير اختبار واحد، شهادة جودة واحدة وضمان الجودة، لوحتان، شريطان، لوحة عمياء واحدة، مجموعة واحدة من لوحة الواجهة، مجموعة واحدة من المكونات الناعمة من مطاط السيليكونبناءهالرذاذ مفاجئ من ألواح الصلب المدرفلة على البارد (أبيض عاجي) الخزان الداخليصفائح وصفائح من الفولاذ المقاوم للصدأمادة عازلة للحرارة رغوة البولي يوريثانتبريد طريقة التبريدوضع التبريد للضاغط المكدس (الماء المبرد)ثلاجةعجلة الوادي الألمانية ضاغط شبه مغلقنافذة المراقبة (مم) 400*500 اتصال الصك (مم)واحد على الجانبين الأيسر والأيمنΦ100المراقب الماليشاشة LCD ملونة تعمل باللمسجهاز التسجيلمسجل درجة الحرارة والرطوبة (اختياري) واجهة الاتصالاتواجهة RS485 واجهة RS232. برنامج تشغيل الكمبيوتر في الموضع العلوي (اختياري)
    إقرأ المزيد
  • غرفة اختبار الضغط العالي والمنخفض ودرجة الحرارة المنخفضة غرفة اختبار الضغط العالي والمنخفض ودرجة الحرارة المنخفضة
    Nov 12, 2014
    غرفة اختبار درجات الحرارة العالية والمنخفضة والضغط المنخفضال غرفة اختبار الضغط المنخفض يستخدم بشكل رئيسي في مجالات الطيران والفضاء والمعلومات والإلكترونيات وما إلى ذلك، لتحديد القدرة على التكيف البيئي واختبارات الموثوقية للأدوات والمنتجات الكهربائية والمواد والمكونات والمعدات في ظل تأثيرات فردية أو متزامنة للضغط المنخفض والضغط العالي. درجة الحرارة، ودرجة الحرارة المنخفضة، وقياس معلمات الأداء الكهربائي لقطعة الاختبار عند تنشيطها.مبدأ المنتج ووظيفتهتُستخدم غرفة اختبار الضغط العالي ودرجة الحرارة المنخفضة والضغط المنخفض بشكل أساسي في الطيران والفضاء والإلكترونيات والدفاع الوطني والبحث العلمي والقطاعات الصناعية الأخرى لتحديد اختبار موثوقية التخزين والنقل للمنتجات الكهربائية والإلكترونية (بما في ذلك المكونات والمواد والأدوات) تحت تأثير فردي أو متزامن لدرجات الحرارة العالية والمنخفضة والضغط المنخفض. ويمكن استخدامه أيضًا لاختبار معلمات الأداء الكهربائي للعينات عند تنشيطها.تحرير الجهاز الهيكلي لغرفة اختبار درجات الحرارة العالية والمنخفضة والضغط المنخفض1. الغلاف الخارجي مصنوع من صفائح فولاذية مدلفنة على البارد مرشوشة بالبلاستيك أو الفولاذ المقاوم للصدأ، والغلاف الداخلي مصنوع من الفولاذ المقاوم للصدأ2. طبقة العزل الحراري: الصوف الزجاجي فائق النعومة والبولي يوريثين الصلب3. طريقة التبريد: طريقة التبريد بالضغط (مكثف مبرد بالهواء)4. الثلاجة: وحدة ضاغط Taikang الفرنسية الأصلية المغلقة بالكامل5. السخان: سخان ذو زعانف من الفولاذ المقاوم للصدأ6. نظام الحمل الحراري: مروحة متعددة الشفرات، محرك مخصص لتكييف الهواء7. جهاز التحكم في درجة الحرارة: جهاز التحكم في درجة الحرارة الرقمي الذكي، باستخدام مستشعر PT-l00 للتحكم في درجة الحرارة.8. ترتيب المكونات الكهربائية في خزانة التحكم معقول، والأسلاك نظيفة، ويتم استخدام أطراف الأسلاك المغلفة.9. صمام الملف اللولبي الخروع، صمام التوسع دانفوس10. مضخة فراغ عالية الجودةتحرير نظام الفراغ لغرفة اختبار درجات الحرارة العالية والمنخفضة والضغط المنخفض1. تركيب نظام الفراغ : نظام الفراغ هو مكون يحصل على درجة الفراغ ويقيسها ويتكون من نظام قياس الفراغ ووحدة اكتساب الفراغ2. قياس الفراغ: يتم إجراء قياس الفراغ باستخدام مستشعر الضغط. يستخدم مقياس الفراغ هذا ضغط الضغط لتحقيق قياس الفراغ، وبيانات القياس عبارة عن إشارة كهربائية خطية يمكن إدخالها مباشرة في وحدة التحكم بالجهاز للعرض والتحكمحالة البيئةدرجة الحرارة: 5 درجة مئوية ~ +28 درجة مئوية (متوسط درجة الحرارة خلال 24 ساعة ≥ 28 درجة مئوية)الرطوبة النسبية: ≥ 85% رضغط الهواء: 86 كيلو باسكال ~ 106 كيلو باسكالظروف إمداد الطاقة: أسلاك ثلاثية الطور + سلك أرضي واقٍ، نطاق الجهد: تيار متردد (380 ± 38) فولتنطاق تذبذب التردد المسموح به: (50 ± 0.5) هرتزمقاومة التأريض لسلك التأريض الواقي أقل من 4 أومالمواصفات الفنية لغرفة اختبار درجات الحرارة العالية والمنخفضة والضغط المنخفض1. حجم الاستوديو:FA-4 4 قدم مكعب (113 لتر)-73 درجة مئوية إلى +177 درجة مئويةلا يوجد FA-10 10 قدم مكعب (283 لتر)-73 درجة مئوية إلى +177 درجة مئوية20% إلى 95% رطوبة نسبية FA-16 16 قدم مكعب (453 لتر)-73 درجة مئوية إلى +177 درجة مئوية20% إلى 95% رطوبة نسبية FA-35 35 قدم مكعب (991 لتر)-73 درجة مئوية إلى +177 درجة مئوية20% إلى 95% رطوبة نسبية FA-64 64 قدم مكعب (1812 لتر)-73 درجة مئوية إلى +177 درجة مئوية20% إلى 95% رطوبة نسبية FA-96 96 قدم مكعب (2718 لتر)-73 درجة مئوية إلى +177 درجة مئوية20% إلى 95% رطوبة نسبية 2. نطاق درجة الحرارة: -40~150 درجة مئوية3. انحراف درجة الحرارة: ± 2 درجة مئوية4. تقلبات درجة الحرارة: ± 0.5 درجة مئوية5. توحيد درجة الحرارة: ≥ 2 ℃6. مستوى ضغط الهواء: 4-84kpa7. معدل التسخين 1.0-3.0 درجة مئوية/دقيقة8. معدل التبريد 0.7-1.0 درجة مئوية/دقيقة9. وحدة تحكم نظام التحكم Siemens PLC، شاشة LCD ملونة تعمل باللمس من Siemens10. دقة ضبط نطاق الدقة: درجة الحرارة ± 0.1 درجة مئوية، دقة الإشارة: درجة الحرارة ± 0.1 درجة مئوية، الدقة: ± 0.1 درجة مئوية11. مستشعر درجة الحرارة مقاومة البلاتين PT100 Ω/MV12. جهاز إرسال الضغط الإلكتروني بمستشعر الضغط13. نظام تسخين مستقل تمامًا، سخان تسخين كهربائي من سبائك النيكل والكروم14. نظام التبريد: طريقة التبريد الضاغط أحادي المرحلة/المتسلسلة الفرنسية الأصلية "Taikang" والمبردة بالهواء بالكامل15. محرك تكييف الهواء مقاوم للحرارة ومنخفض الضوضاء لنظام الدوران. مروحة طرد مركزي متعددة الشفراتجهاز حماية السلامة1. الزائد وحماية ماس كهربائى2. حماية من درجة الحرارة الزائدة3. حماية الضغط العالي والمنخفض لوحدة التبريد4. موجه صوت التنبيهوصف وحدة التحكم Q8-902 لغرفة اختبار درجة الحرارة المنخفضة والضغط المنخفضواجهة التشغيلواجهة صينية تعمل باللمس، مع شاشة رقمية، ومنحنى في الوقت الفعلي، واختيار التشغيل، وإعداد التوقيت، وإعداد البرنامج، والتنبيه، وإعداد المعلمات والواجهات الأخرىوظيفة تسجيل المنحنىيمكن حفظ القيم المحددة وقيم أخذ العينات ووقت أخذ العينات للجهاز؛ الحد الأقصى لوقت التخزين هو 30 يومًا. تخزين 5 منحنيات في الوقت الفعلي بسعات ودقة مختلفة في الوقت نفسه لمدة 30 يومًا، و7 أيام، و24 ساعة، و8 ساعات، وساعة واحدة، وعرض البيانات في الوقت الفعلي لتلبية احتياجات المستخدمين المختلفةوظيفة الطباعةطابعة صغيرة قابلة للتوصيل (اختيارية)قدرة البرنامجالبرنامج: ما يصل إلى 30 منحنياتشريحة البرنامج: يمكن أن يحتوي كل برنامج على ما يصل إلى 50 شريحة (إجمالي شريحة البرنامج 1200 شريحة)تجميع شرائح البرنامج: يمكن تجميع كل منحنى إلى شرائح وفقًا لأي مقطع مستمر، ويمكن دمج ما يصل إلى 10 شرائح كحد أقصى، ويُسمح للقطاعات بالتداخلالحلقة الداخلية: يتم تكرار مقاطع البرنامج داخل البرنامج في أقسام كحد أدنى لوحدة الحلقة، بحد أقصى 99 حلقة لكل قسمحلقة البرنامج: يمكن تكرارها حتى 99 مرةاتصال البرنامج: بعد تشغيل البرنامج، يمكنه الاتصال بالبرنامج التالي المحددالمعايير ذات الصلةبالإضافة إلى المحتوى المحدد في هذه المتطلبات الفنية، فإن المعدات تلبي متطلبات GB/T10591 وGB/T10592.البيانات والخدمات1. توفير المعلومات الفنية مثل المخططات الكهربائية وقوائم الأجزاء المستهلكة وأدلة التشغيل والصيانة للمعدات، بالإضافة إلى المعلومات الفنية للأجزاء الداعمة الرئيسية التي تم شراؤها.2. تدريب 1-2 من موظفي تشغيل وصيانة المعدات لإتقان مهارات التشغيل ومهارات الإصلاح والصيانة العامة للمعدات بشكل كامل.خلال عام واحد من تاريخ قبول المعدات، يتم توفير خدمة ما بعد البيع مجانًا للمشتري، وبعد عام واحد، يتم توفير ملحقات المعدات للمشتري بسعر التكلفة.
    إقرأ المزيد
  • ER-135MHP-W ، خطوة في درجة حرارة ثابتة وحمام الرطوبة ، درجة حرارة ثابتة وكتاب نمط غرفة الرطوبة (مبرد بالماء) ER-135MHP-W ، خطوة في درجة حرارة ثابتة وحمام الرطوبة ، درجة حرارة ثابتة وكتاب نمط غرفة الرطوبة (مبرد بالماء)
    Nov 10, 2014
    ER-135MHP-W، خطوة في حمام درجة حرارة ورطوبة ثابتة، كتاب على شكل غرفة درجة حرارة ورطوبة ثابتة (مبرد بالماء)مشروعيكتباستمارةإيه - 135 ميجا حصان - دبليو طبيعةقدرة*1*2وضع درجة الحرارة والرطوبةطريقة الكرة الرطبةنموذج درجة الحرارة والرطوبة *3-40~+ 80 درجة مئوية /10~95% رطوبة نسبيةسعة القطب لدرجة الحرارة والرطوبة± 0.3 درجة مئوية / ± 2.5% رطوبة نسبيةتوزيع درجة الحرارة والرطوبة± 0.75 درجة مئوية / ± 5.0% رطوبة نسبيةتنخفض درجة الحرارة الوقت+20~ -40 درجة مئوية خلال 170 دقيقةوقت ارتفاع درجة الحرارة+20~+ 80 درجة مئوية خلال 50 دقيقةقيمة الضوضاء*6غرفة بالخارج65 ديسيبلالجانب الداخلي79 بقدرة التجميد القانونية (50 / 60 هرتز)2.57/2.81 طريقة شكل المنتج بالبوصة (العرض والعمق والارتفاع)يرجى الرجوع إلى مخطط التكوين   مختبر لوحة المستودعاتمنطقة السرير13 . 0 م2 طريقة شكل البوصة*7واسع3600 ملمعميق3600 ملمعالي2325 ملميملك نفسهطريقة التكثيف*7واسع3450 ملمعميق3450 ملمعالي2100 ملمالمواد الخارجيةصفيحة فولاذية مطلية بالعاجداخل المادةلوحة الفولاذ المقاوم للصدأ (SUS304)مادة حرارية مكسورةراتنجات صناعية صلبةمقاومة الوزن للمجلس5.9 ك نيوتن/ م2 {600 كجم ق / م2 }الباب (العرض والارتفاع)830 مم × 1800 مم قطعة واحدة مفتوحةالقياس (العرض والارتفاع)190 مم × 320 مم البابسعة الضوء الداخلي (الكمية)60 واط (2 فرد)فتحة الكابلφ 50 1 (500 مم من ارتفاع سطح السرير، جانب واحد)نموذج التحكم وطريقة الشكلواسعة وعميقة وعاليةالاتحاد الأوروبي - 6 5MH*2 وحدة 1200 مم × 710 مم × 1940 مم الزي الخارجي داخلي صفائح وألواح من الفولاذ المقاوم للصدأ (SUS304) في الهواء الطلق لون طلاء L على لوح فولاذي؛ اللون العاجي: علامة جدول الألوان 2.5Y8/2)تشغيللون طلاء لوحة الصلب. اللون العاجي: علامة جدول الألوان 2.5Y8/2 يمكن للمرء أن يتقلص الآلةوسط التبريدR404Aمخرج الفريزر 1 (الموظفين)2.2 كيلو واط (1) × 2التبريد ومزيل الرطوبةنوع المشتت الحراري المختلط متعدد القنواتالمكثف (عدد الموظفين)نوع الزعنفة المستعرضة (2) 2مسعراستمارةسخان سبائك النيكل والكروم المقاوم للحرارةمقدار5 . 7 كيلو واط (3 φ 200 فولت) × 2المرطباستمارةSUS 316L اصنع جهاز ترطيب سطحي بالبخارمقدار5 . 4 كيلو واط (3 φ 200 فولت) × 2جهاز إمداد الهواءالنموذج (الكمية)مروحة هواء واحدة متعددة الشفرات (1)البقاء على قيد الحياة خارج الجهاز0 باسكال{0 ملماق}معدل النفخ25 (م3/دقيقة)العودة إلى الرحم1100 (ص / دقيقة)شكل المحركفتفو-كخرج المحرك (رقم القطب)0.75 كيلو واط (6) × 2ترطيب إمدادات المياهتثبيت اسطوانة إمدادات المياهنوعية المياه * 8الموصلية الكهربائية أقل من 10 ميكرو ثانية / سممقدار4 لتر × 2مياه التغذيةطريققرص مرطب نوع الجاذبية قرص فتيل الكرة الرطبنوع الصمام الكهرومغناطيسيالمراقب الماليتم ضبط درجة الحرارة-42.0 ~+ 82.0 درجة مئويةتم ضبط الرطوبة0~98% رطوبة نسبية (درجة حرارة اللمبة الجافة 10 درجة مئوية ~ 80 درجة مئوية)ضبط الوقت فاني0 ~ 999 الوقت 59 نقطة (نوع مبرمج) 0 ~ 20000 الوقت 59 نقطة (القيمة)ضبط طاقة التحللدرجة الحرارة 0.1 درجة مئوية، الرطوبة 1% رطوبة نسبية، الوقت 1 دقيقةتشير إلى الدقة درجة الحرارة ± 0.8 درجة مئوية (النوع)، الرطوبة ± 1% رطوبة نسبية (النوع)، الوقت ± 100 جزء في المليوننوع الإجازةالقيمة أو البرنامجرقم المرحلة20 مرحلة / 1 استمارةعدد الإجراءاتعدد برامج القوة الواردة (RAM) بحد أقصى 32 برنامجًا / برامج ROM داخلية بحد أقصى 13 برنامجًارقم الرحلة ذهابا وإياباالحد الأقصى 98 أو غير محدودعدد مرات تكرار الرحلة ذهابًا وإيابًاالحد الأقصى 3 مراتإزاحة النهايةJP t 100Ω (at 0 ℃)، الصف B (JIS C1604-1997)عمل التحكمعند تقسيم الإجراء PIDوظيفة الفيروس الداخليوظيفة التسليم المبكر، وظيفة الاستعداد، تحديد وظيفة صيانة القيمة، وظيفة حماية انقطاع التيار الكهربائي،وظيفة اختيار عمل الطاقة، وظيفة الصيانة، وظيفة النقل ذهابًا وإيابًا،وظيفة تسليم الوقت، وظيفة إخراج إشارة الوقت، وظيفة منع الإفراط في التبريد الزائد،وظيفة التمثيل غير الطبيعي، وظيفة إخراج التنبيه الخارجي، إعداد وظيفة تمثيل النموذج،وظيفة اختيار نوع النقل، يمثل وقت الحساب الوظيفة، وظيفة مصباح الفتحةمشروعيكتباستمارةإيه - 55 ميجا حصان - دبليوآلة التحكم في درجة الحرارةلوحة التحكمآلة المعداتلوحة تشغيل LCD ملونة (وضع الاتصال القسري)،يمثل المصباح (مصدر الطاقة، النقل، غير الطبيعي)، اختبار نظام إمداد الطاقة بالمواد الطرفية الملكية،محطة إنذار خارجية، محطة إخراج إشارة الوقت، موصل سلك الطاقة، جهاز الحماية لوحة مستودع اختبار تجويف الرحممادة الاختبار معوظيفة منع ارتفاع درجة الحرارة (الكمبيوتر الصغير: الإعداد التلقائي)ارتفاع درجة الحرارة ثالثًا (ضبط: أعلى من 60 درجة مئوية)دورة التبريدجهاز حماية الزائد، جهاز حجب عاليةمسعرجهاز حماية من ارتفاع درجة الحرارة، مصهر درجة الحرارة المرطب جهاز منع احتراق الهواء (2 وزن)، منظم لمستوى المياه المبللةمنفاخجهاز حماية الزائدلوحة التحكمقاطع التسرب لإمدادات الطاقة، الصمامات (للسخان، المرطب)،المصهر (لحلقة التشغيل)، مرحل منع عكس المروحةبالإضافة إلى السيطرةنظام الصقيعطريقة إزالة الجليد * 5إيقاف دورة إزالة الجليد (توقف نقل الفريزر)،تسخين إزالة الجليدالسيطرة الباردةلكن النظامماء وضع التحكم في التكثيف (الكمية) صمام صنع الماء لتبريد الماء (2) 2يكرريقيسالثرمستات (يعمل)300 كجم × 2كهرباءإنديسبس سينينسيسخاصطبيعةمصدرالاتصالات ثلاث مراحل  380 فولت 50 هرتزالحد الأقصى للحمل الحالي45 أمبير × 2يستخدم مصدر الطاقة قاطع التسرب60 أمبير (التيار الحسي 30 مللي أمبير) × 2توزيع الطاقةخرطوم عازل مطاط 22م2×2خشونة سلك التأريض5.5 م2×2باردتراجعماء*9 محصول الماء؛ محصول الماء 40 لتر / دقيقة (درجة حرارة الماء الداخل 32 درجة مئوية) × 2ضغط الماء0.1 ~ 0.5 م باسكال { 1.0 ~ 5.0 كجم / سم 2 } درجة حرارة الماء 18~32 درجة مئويةطريقة بوصة الأنابيبمدخل / خروجمقعد الوالدين PT 1 / مقعد الوالدين PT 1طريقة توزيع أنابيب إمداد المياه المرطبة * 8PT 1 / 2 مقعد الوالدينيرتبماءطريقة بوصة الأنابيبأنبوب التصريفPT 1 / 2 مقعد الوالدينإنه المنتجات المنتجة (الموظفون) خفض الضغط(1) * 8فتيل الكرة الرطبة (15)خذ التعليمات (1)
    إقرأ المزيد
  • تطبيق غرفة دورة درجة حرارة TCT في صناعة الاتصالات البصرية تطبيق غرفة دورة درجة حرارة TCT في صناعة الاتصالات البصرية
    Sep 27, 2024
    تطبيق غرفة دورة درجة الحرارة TCT في صناعة الاتصالات البصريةإن وصول 5G يجعل الناس يشعرون بالتطور السريع للإنترنت عبر الهاتف المحمول، كما تم تطوير تكنولوجيا الاتصالات البصرية كأساس مهم. في الوقت الحاضر، قامت الصين ببناء أطول شبكة ألياف ضوئية في العالم، ومع التقدم المستمر لتكنولوجيا 5G، سيتم استخدام تكنولوجيا الاتصالات البصرية على نطاق أوسع. إن تطوير تكنولوجيا الاتصالات البصرية لا يسمح للناس بالاستمتاع بسرعة شبكة أسرع فحسب، بل يجلب أيضًا المزيد من الفرص والتحديات. على سبيل المثال، تتطلب التطبيقات الجديدة مثل الألعاب السحابية والواقع الافتراضي والواقع المعزز شبكات أكثر استقرارًا وعالية السرعة، ويمكن لتكنولوجيا الاتصالات البصرية تلبية هذه الاحتياجات. وفي الوقت نفسه، جلبت تكنولوجيا الاتصالات البصرية أيضًا المزيد من فرص الابتكار، مثل الرعاية الطبية الذكية والتصنيع الذكي وغيرها من المجالات، وسوف تستخدم تكنولوجيا الاتصالات البصرية لتحقيق عملية أكثر كفاءة ودقة. لكن هل تعرف ماذا؟ لا يمكن تحقيق هذه التكنولوجيا المذهلة دون الاعتماد على معدات الاختبار البيئية الكلية، وخاصة غرفة اختبار دورة درجة الحرارة TC، وهي غرفة اختبار التغير السريع في درجة الحرارة. تقدم لك هذه المقالة مدير جودة اختبار موثوقية منتج الاتصالات البصرية - مختبر التغير السريع في درجة الحرارة.أولاً، دعونا نتحدث بإيجاز عن الاتصال البصري. يقول بعض الأشخاص أيضًا أنه يسمى الاتصال البصري، لذا فإنهما في النهاية ليس مفهومًا. في الواقع، هما اثنان من نفس المفهوم. الاتصال البصري هو استخدام الإشارات الضوئية لتكنولوجيا الاتصالات، ويعتمد الاتصال البصري على الاتصال البصري، من خلال الأجهزة البصرية مثل الألياف الضوئية، والكابلات الضوئية لتحقيق نقل البيانات. تُستخدم تكنولوجيا الاتصالات البصرية على نطاق واسع، مثل استخدامنا اليومي للنطاق العريض للألياف الضوئية وأجهزة الاستشعار الضوئية للهاتف المحمول والقياس البصري في الفضاء الجوي وما إلى ذلك. ويمكن القول أن الاتصالات البصرية أصبحت جزءا هاما من مجال الاتصالات الحديثة. فلماذا يحظى الاتصال البصري بشعبية كبيرة؟ في الواقع، لديها العديد من المزايا، مثل النقل عالي السرعة وعرض النطاق الترددي الكبير والخسارة المنخفضة وما إلى ذلك.تشمل منتجات الاتصالات البصرية الشائعة ما يلي: الكابلات الضوئية، ومفاتيح الألياف، ومودم الألياف، وما إلى ذلك، المستخدمة لإرسال واستقبال الإشارات الضوئية لمعدات اتصالات الألياف الضوئية؛ يمكن لمستشعر درجة الحرارة، ومستشعر الضغط، ومستشعر الإزاحة، وما إلى ذلك، قياس الكميات الفيزيائية المختلفة في الوقت الفعلي وأجهزة استشعار الألياف الضوئية الأخرى؛ مضخم بصري مخدر بالإربيوم، مضخم بصري مخدر بالإربيوم، مضخم رامان، وما إلى ذلك، يستخدم لتوسيع شدة الإشارات الضوئية ومكبرات الصوت الضوئية الأخرى؛ ليزر الهليوم النيون، ليزر الصمام الثنائي، ليزر الألياف، وما إلى ذلك، هي مصادر للضوء في الاتصالات البصرية، وتستخدم لإنتاج سطوع عالي، ضوء ليزر اتجاهي ومتماسك وأشعة ليزر أخرى؛ أجهزة الكشف الضوئية، والمحددات البصرية، والثنائيات الضوئية، وما إلى ذلك، لاستقبال الإشارات الضوئية وتحويلها إلى إشارات كهربائية وأجهزة استقبال بصرية أخرى؛ يتم استخدام المفاتيح الضوئية والمعدلات الضوئية والمصفوفات الضوئية القابلة للبرمجة وما إلى ذلك للتحكم في إرسال وتوجيه الإشارات الضوئية وضبطها وأجهزة التحكم الضوئية الأخرى. لنأخذ الهواتف المحمولة كمثال ونتحدث عن تطبيق منتجات الاتصالات البصرية على الهواتف المحمولة:1. الألياف الضوئية: تُستخدم الألياف الضوئية عمومًا كجزء من خط الاتصال، نظرًا لسرعة نقلها السريعة، ولا تتأثر إشارات الاتصال بسهولة بالتداخل الخارجي والخصائص الأخرى، وقد أصبحت جزءًا مهمًا من اتصالات الهاتف المحمول.2. المحول الكهروضوئي/الوحدة الضوئية: المحول الكهروضوئي والوحدة الضوئية عبارة عن أجهزة تقوم بتحويل الإشارات الضوئية إلى إشارات كهربائية، وهي أيضًا جزء مهم جدًا من اتصالات الهاتف المحمول. في عصر الاتصالات عالية السرعة مثل 4G و5G، يجب تحسين سرعة وأداء هذه المعدات بشكل مستمر لتلبية احتياجات الاتصال السريع والمستقر.3. وحدة الكاميرا: في الهاتف المحمول، تشتمل وحدة الكاميرا عمومًا على CCD وCMOS وعدسة بصرية وأجزاء أخرى، كما أن لجودتها وأدائها تأثيرًا كبيرًا على جودة الاتصال البصري للهاتف المحمول.4. العرض: تستخدم شاشات الهواتف المحمولة عمومًا تقنيات OLED وAMOLED وغيرها من التقنيات، ويرتبط مبدأ هذه التقنيات بالبصريات، ولكنها أيضًا جزء مهم من الاتصالات البصرية للهاتف المحمول.5. مستشعر الضوء: يستخدم مستشعر الضوء بشكل أساسي في الهواتف المحمولة لاستشعار الضوء البيئي واستشعار القرب والاستشعار عن طريق الإيماءات، وهو أيضًا منتج اتصالات بصري مهم للهاتف المحمول.يمكن القول أن منتجات الاتصالات البصرية تملأ جميع جوانب حياتنا وعملنا. ومع ذلك، فإن بيئة إنتاج واستخدام منتجات الاتصالات البصرية غالبًا ما تكون قابلة للتغيير، مثل بيئة الطقس ذات درجة الحرارة المرتفعة أو المنخفضة عند العمل في الهواء الطلق، أو أن الاستخدام لفترة طويلة سيواجه أيضًا تغيرات في التمدد الحراري والانكماش. فكيف يتم تحقيق الاستخدام الموثوق لهذه المنتجات؟ يجب أن نذكر بطل الرواية لدينا اليوم - غرفة اختبار التغير السريع في درجة الحرارة، والمعروفة أيضًا باسم صندوق TC في صناعة الاتصالات البصرية. من أجل ضمان أن منتجات الاتصالات البصرية لا تزال تعمل بشكل طبيعي في ظل الظروف البيئية المختلفة، من الضروري إجراء اختبارات التغير السريع في درجة الحرارة على منتجات الاتصالات البصرية. يمكن لغرفة اختبار التغير السريع في درجة الحرارة محاكاة مجموعة متنوعة من بيئات درجة الحرارة والرطوبة المختلفة، ومحاكاة التغيرات البيئية الشديدة اللحظية في العالم الحقيقي ضمن نطاق سريع. إذًا كيف يتم تطبيق غرفة اختبار التغير السريع في درجة الحرارة في صناعة الاتصالات البصرية؟1. اختبار أداء الوحدة الضوئية: الوحدة الضوئية هي مكون رئيسي للاتصالات البصرية، مثل جهاز الإرسال والاستقبال البصري، ومكبر الصوت البصري، والمفتاح البصري، وما إلى ذلك. يمكن لغرفة اختبار التغير السريع في درجة الحرارة محاكاة بيئات درجات الحرارة المختلفة واختبار أداء الوحدة البصرية عند درجات حرارة مختلفة لتقييم قدرتها على التكيف والموثوقية.2. اختبار موثوقية الأجهزة البصرية: تشمل الأجهزة البصرية الألياف الضوئية، وأجهزة الاستشعار الضوئية، والشبك، والبلورات الضوئية، والثنائيات الضوئية، وما إلى ذلك. يمكن لغرفة اختبار التغير السريع في درجة الحرارة اختبار التغير في درجة حرارة هذه الأجهزة البصرية وتقييم موثوقيتها وعمرها على أساس نتائج الاختبار.3. اختبار محاكاة نظام الاتصالات البصرية: يمكن لغرفة اختبار التغير السريع في درجة الحرارة محاكاة الظروف البيئية المختلفة في نظام الاتصالات البصرية، مثل درجة الحرارة والرطوبة والاهتزاز وما إلى ذلك، لاختبار الأداء والموثوقية والاستقرار للنظام بأكمله.4. البحث والتطوير التكنولوجي: صناعة الاتصالات البصرية هي صناعة كثيفة الاستخدام للتكنولوجيا، وتحتاج إلى التطوير المستمر لتقنيات جديدة ومنتجات جديدة. يمكن استخدام غرفة اختبار التغير السريع في درجة الحرارة لاختبار أداء وموثوقية المنتجات الجديدة، مما يساعد على تسريع تطوير المنتجات الجديدة وتسويقها.باختصار، يمكن ملاحظة أنه في صناعة الاتصالات البصرية، تُستخدم غرفة اختبار التغير السريع في درجة الحرارة عادةً لاختبار أداء وموثوقية الوحدات البصرية والأجهزة البصرية. ثم عندما نستخدم غرفة اختبار التغير السريع في درجة الحرارة للاختبار، قد تتطلب منتجات الاتصالات البصرية المختلفة معايير مختلفة. فيما يلي معايير اختبار التغير السريع في درجة الحرارة لبعض منتجات الاتصالات البصرية الشائعة:1. الألياف الضوئية: معايير الاختبار الشائعة هناك معايير اختبار شائعة للتغير السريع في درجة الحرارة للألياف الضوئية وهي كما يلي: IEC 61300-2-22: يحدد المعيار طريقة اختبار الثبات والمتانة لمكونات الألياف الضوئية، ويحدد القسم 4.3 منها درجة الحرارة طريقة اختبار ثبات مكونات الألياف الضوئية، في حالة التغيرات السريعة في درجات الحرارة لمكونات الألياف الضوئية للقياس والتقييم. GR-326-CORE: تحدد هذه المواصفة القياسية متطلبات اختبار الموثوقية لموصلات ومحولات الألياف الضوئية، بما في ذلك اختبارات الثبات الحراري لتقييم موثوقية موصلات ومحولات الألياف الضوئية في البيئات المتغيرة لدرجة الحرارة. GR-468-CORE: تحدد هذه المواصفة القياسية مواصفات الأداء وطرق الاختبار لموصلات الألياف الضوئية، بما في ذلك اختبار دورة درجة الحرارة، واختبار التقادم المتسارع، وما إلى ذلك، للتحقق من موثوقية واستقرار موصلات الألياف الضوئية في ظل ظروف بيئية مختلفة. ASTM F2181: تحدد هذه المواصفة القياسية طريقة لاختبار فشل الألياف في ظل ظروف بيئية ذات درجة حرارة عالية ورطوبة عالية لتقييم متانة الألياف على المدى الطويل. ويتم اختبار وتقييم المعايير المذكورة أعلاه، مثل GB/T 2423.22-2012، من حيث موثوقية الألياف الضوئية في التغيرات السريعة في درجات الحرارة أو بيئات درجات الحرارة العالية والرطوبة العالية على المدى الطويل، والتي يمكن أن تساعد غالبية الشركات المصنعة على ضمان الجودة والموثوقية. من منتجات الألياف الضوئية.2. المحول الكهروضوئي/الوحدة الضوئية: معايير اختبار التغير السريع في درجة الحرارة الشائعة هي GB/T 2423.22-2012، GR-468-CORE، EIA/TIA-455-14 وIEEE 802.3. تغطي هذه المعايير بشكل أساسي طرق الاختبار وخطوات التنفيذ المحددة للمحولات الكهروضوئية/الوحدات الضوئية، والتي يمكن أن تضمن أداء وموثوقية المنتجات في بيئات درجات الحرارة المختلفة. من بينها، معيار GR-468-CORE مخصص خصيصًا لمتطلبات الموثوقية للمحولات الضوئية والوحدات الضوئية، بما في ذلك اختبار دورة درجة الحرارة واختبار الحرارة الرطبة وغيرها من الاختبارات البيئية، التي تتطلب المحولات الضوئية والوحدات الضوئية للحفاظ على أداء مستقر وموثوق به على المدى الطويل. -استخدام المصطلح.3. المستشعر البصري: معايير اختبار التغير السريع في درجة الحرارة الشائعة هي GB/T 27726-2011، IEC 61300-2-43 وIEC 61300-2-6. تغطي هذه المعايير بشكل أساسي طرق الاختبار وخطوات التنفيذ المحددة لاختبار تغير درجة الحرارة للمستشعر البصري، والتي يمكن أن تضمن أداء وموثوقية المنتج في بيئات درجات الحرارة المختلفة. من بينها، معيار GB/T 27726-2011 هو المعيار لطريقة اختبار أداء أجهزة الاستشعار الضوئية في الصين، بما في ذلك طريقة الاختبار البيئي لأجهزة استشعار الألياف الضوئية، والتي تتطلب من المستشعر البصري الحفاظ على أداء مستقر في مجموعة متنوعة من بيئات العمل . معيار IEC 60749-15 هو المعيار الدولي لاختبار دورة درجة الحرارة للمكونات الإلكترونية، وله أيضًا قيمة مرجعية لاختبار التغير السريع في درجة الحرارة لأجهزة الاستشعار البصرية.4. الليزر: معايير اختبار التغير السريع في درجة الحرارة الشائعة هي GB/T 2423.22-2012 "الاختبار البيئي للمنتجات الكهربائية والإلكترونية الجزء 2: اختبار ملحوظة: اختبار دورة درجة الحرارة"، GB/T 2423.38-2002 "طرق الاختبار الأساسية للمكونات الكهربائية الجزء 38 : اختبار مقاومة درجة الحرارة (IEC 60068-2-2)، GB/T 13979-2009 "طريقة اختبار أداء منتج الليزر"، IEC 60825-1، IEC/TR 61282-10 ومعايير أخرى تغطي بشكل أساسي طريقة اختبار تغير درجة حرارة الليزر و خطوات التنفيذ المحددة يمكنها ضمان أداء وموثوقية المنتجات في بيئات درجات الحرارة المختلفة، ومن بينها، معيار GB/T 13979-2009 هو المعيار لطريقة اختبار أداء منتجات الليزر في الصين، بما في ذلك طريقة الاختبار البيئي. الليزر تحت التغيرات في درجات الحرارة، مما يتطلب من الليزر الحفاظ على أداء مستقر في مجموعة متنوعة من بيئات العمل. يعد معيار IEC 60825-1 بمثابة مواصفات لسلامة منتجات الليزر، وهناك أيضًا أحكام ذات صلة باختبار التغير السريع في درجة حرارة الليزر. بالإضافة إلى ذلك، يعد معيار IEC/TR 61282-10 أحد المبادئ التوجيهية لتصميم أنظمة اتصالات الألياف الضوئية، والذي يتضمن طرقًا لحماية البيئة من أشعة الليزر.5. جهاز التحكم البصري: معايير اختبار التغير السريع في درجة الحرارة الشائعة هي GR-1209-CORE وGR-1221-CORE. GR-1209-CORE هو معيار موثوقية لمعدات الألياف الضوئية، وذلك بشكل أساسي لاختبار موثوقية التوصيلات الضوئية، ويحدد تجربة الموثوقية لأنظمة التوصيل البصري. من بينها، تعد دورة درجة الحرارة السريعة (FTC) أحد مشاريع الاختبار، والتي تهدف إلى اختبار موثوقية وحدات الألياف الضوئية في ظل ظروف درجات الحرارة المتغيرة بسرعة. أثناء الاختبار، تحتاج وحدة التحكم الضوئية إلى إجراء دورة درجة حرارة في نطاق -40 درجة مئوية إلى 85 درجة مئوية. أثناء دورة درجة الحرارة، يجب أن تحافظ الوحدة على وظيفتها الطبيعية وألا تنتج مخرجات غير طبيعية، ووقت الاختبار هو 100 دورة درجة حرارة . GR-1221-CORE هو معيار موثوقية لأجهزة الألياف الضوئية السلبية وهو مناسب لاختبار الأجهزة السلبية. من بينها، يعد اختبار دورة درجة الحرارة أحد عناصر الاختبار، والذي يتطلب أيضًا اختبار وحدة التحكم الضوئية في نطاق -40 درجة مئوية إلى 85 درجة مئوية، ووقت الاختبار هو 100 دورة. يحدد كلا المعيارين اختبار موثوقية وحدة التحكم الضوئية في بيئة تغير درجة الحرارة، والتي يمكن أن تحدد استقرار وموثوقية وحدة التحكم الضوئية في ظل الظروف البيئية القاسية.بشكل عام، قد تركز معايير اختبار التغير السريع في درجة الحرارة المختلفة على معلمات الاختبار وطرق الاختبار المختلفة، فمن المستحسن اختيار معايير الاختبار المقابلة وفقًا لاستخدام منتجات محددة.في الآونة الأخيرة، عندما نناقش التحقق من موثوقية الوحدات الضوئية، هناك مؤشر متناقض، عدد دورات درجة الحرارة للتحقق من الوحدات الضوئية، هناك 10 مرات، و20 مرة، و100 مرة، أو حتى 500 مرة.تعريفات التردد في اثنين من معايير الصناعة:المراجع لهذه المعايير لها مصادر واضحة وصحيحة.بالنسبة للوحدة الضوئية الأمامية 5G، نرى أن عدد الدورات هو 500، ويتم ضبط درجة الحرارة على -40 درجة مئوية ~ 85 درجة مئويةفيما يلي وصف 10/20/100/500 أعلاه في النص الأصلي لـ GR-468(2004)نظرًا للمساحة المحدودة، تقدم هذه المقالة استخدام غرفة اختبار التغير السريع في درجة الحرارة في صناعة الاتصالات البصرية. إذا كان لديك أي أسئلة عند استخدام غرفة اختبار التغير السريع في درجة الحرارة وغيرها من معدات الاختبار البيئي، فنحن نرحب بك للمناقشة معنا والتعلم معًا.
    إقرأ المزيد

اترك رسالة

اترك رسالة
إذا كنت مهتما بمنتجاتنا وتريد معرفة المزيد من التفاصيل ، فالرجاء ترك رسالة هنا ، وسوف نقوم بالرد عليك في أقرب وقت ممكن.
إرسال

وطن

منتجات

واتس اب

اتصل بنا