شعار
وطن

غرف اختبار درجة حرارة ورطوبة ثابتة قابلة للبرمجة

غرف اختبار درجة حرارة ورطوبة ثابتة قابلة للبرمجة

  • Structural characteristics of temperature and humidity control test chamber Structural characteristics of temperature and humidity control test chamber
    Oct 16, 2024
    Structural characteristics of temperature and humidity control test chamber Suitable for various small electrical appliances, instruments, materials, and components for wet heat testing, it is also suitable for conducting aging tests. This test chamber adopts the most reasonable structure and stable and reliable control method currently available, making it aesthetically pleasing, easy to operate, safe, and with high precision in temperature and humidity control. It is an ideal equipment for conducting constant temperature and humidity tests. (1) The test box body is in the form of an integral structure, with the refrigeration system located at the lower rear of the box and the control system located at the upper part of the test box. (2) Inside the air duct interlayer at one end of the studio, there are devices such as heaters, refrigeration evaporators, and fan blades distributed; On the left side of the test box, there is a Ø 50 cable hole, and the test box is a single door (stainless steel embedded door handle) (3) The double-layer high temperature and anti-aging silicone rubber seal can effectively ensure the temperature loss of the test chamber (4) There are observation windows, frost prevention devices, and switchable lighting fixtures on the box door. The observation window adopts multi-layer hollow tempered glass, and the inner adhesive sheet conductive film is heated and defrosted. The lighting fixtures adopt imported brand Philips lamps, which can effectively observe the experimental changes in the studio from all angles. The refrigeration cycle of the temperature and humidity control box adopts the reverse Carnot cycle, which consists of two isothermal processes and two adiabatic processes. The process is as follows: the refrigerant is adiabatically compressed to a higher pressure by the compressor, and the work consumed increases the exhaust temperature. Then, the refrigerant exchanges heat with the surrounding medium through the condenser and transfers heat to the surrounding medium. After the refrigerant undergoes adiabatic expansion through the shut-off valve, the temperature of the refrigerant decreases. Finally, the refrigerant absorbs heat from the object at a higher temperature through the evaporator, causing the temperature of the cooled object to decrease. This cycle repeats itself to achieve the goal of cooling down. The refrigeration system design of this test chamber applies energy regulation technology, which can ensure the normal operation of the refrigeration unit and effectively adjust the energy consumption and refrigeration capacity of the refrigeration system, so as to maintain the refrigeration system in the optimal operating state. By using Balanced Temperature Control (BTC), the control system automatically calculates the output of the heater based on the set temperature point through PID calculation when the refrigeration system is working continuously, ultimately achieving a dynamic balance. Dear customer:   Hello, our company is a high-quality development team with strong technical strength, providing high-quality products, complete solutions, and excellent technical services to our customers. The main products include walk-in constant temperature and humidity testing chambers, UV accelerated aging testing machines, rapid temperature change testing chambers, walk-in environmental testing chambers, UV aging testers, constant temperature and humidity chambers, etc. Our company adheres to the principle of building a business with integrity, maintaining quality, and striving for progress. With a more determined pace, we continuously climb new heights and contribute to the national automation industry. We welcome new and old customers to confidently choose the products they like. We will serve you wholeheartedly!
    إقرأ المزيد
  • Service conditions for high, low temperature, and low pressure test chambers Service conditions for high, low temperature, and low pressure test chambers
    Oct 15, 2024
    Service conditions for high, low temperature, and low pressure test chambers One of the usage conditions for high, low temperature, and low pressure test chambers: environmental conditions a、 Temperature: 15 ℃~35 ℃; b、 Relative humidity: not exceeding 85%; c、 Atmospheric pressure: 80kPa~106kPa d、 There is no strong vibration or corrosive gas in the surrounding area; e、 No direct sunlight exposure or direct radiation from other cold or heat sources; f、 There is no strong airflow around, and when the surrounding air needs to be forced to flow, the airflow should not be directly blown onto the box; g、 The influence of magnetic field on the control circuit of the interference free test box in the surrounding area; h、 There is no high concentration of dust or corrosive substances in the surrounding area. Condition 2 for the use of high, low temperature, and low pressure test chambers: Power supply conditions a、 AC voltage: 220V ± 22V or 380V ± 38V; b、 Frequency: 50HZ ± 0.5HZ Condition Three for the Use of High, Low Temperature, and Low Pressure Test Chambers: Water Supply Conditions It is advisable to use tap water or circulating water that meets the following conditions: a、 Water temperature: not higher than 30 ℃; b、 Water pressure: 0.1MPa~0.3MPa; c、 Water quality: meets industrial water standards. Condition 4 for the use of high, low temperature, and low pressure test chambers: Test load conditions The load of the test chamber should meet the following conditions every week: a、 The total mass of the load shall not exceed 80KG per cubic meter within the working chamber volume b、 The total volume of the load shall not exceed 5/1 of the working chamber volume c、 On any cross-section perpendicular to the prevailing wind direction, the sum of the load areas should not exceed 3/1 of the cross-sectional area of the working chamber at that location, and the load should not obstruct the flow of airflow when placed. Dear customer: Our company has products such as rapid temperature change test chambers, UV accelerated weather resistance testing machines, and temperature and humidity control chambers. You can call our service hotline through our website to learn more about our products. Our pursuit is endless, and we welcome new and old customers to choose their favorite products with confidence. We will be dedicated to serving you!
    إقرأ المزيد
  • User selection environment test box must read User selection environment test box must read
    Oct 15, 2024
    User selection environment test box must read 1、 Equipment selection criteria There is currently no exact number of natural environmental factors and induced environmental factors that exist on the surface of the Earth and in the atmosphere, among which there are no less than a dozen factors that have a significant impact on the use and lifespan of engineering products (equipment). Engineers engaged in the study of environmental conditions for engineering products have compiled and summarized the environmental conditions that exist in nature and are induced by human activities into a series of testing standards and specifications to guide the environmental and reliability testing of engineering products. For example, GJB150- the National Military Standard of the People's Republic of China for Environmental Testing of Military Equipment, and GB2423- the National Standard of the People's Republic of China for Environmental Testing of Electrical and Electronic Products, which guides environmental testing of electrical and electronic products. Therefore, the main basis for selecting environmental and reliability testing equipment is the testing specifications and standards of engineering products. Secondly, in order to standardize the tolerance of environmental testing conditions in experimental equipment and ensure the control accuracy of environmental parameters, national technical supervision agencies and various industrial departments have also formulated a series of calibration regulations for environmental testing equipment and detection instruments. Such as the national standard GB5170 of the People's Republic of China "Basic Parameter Calibration Method for Environmental Testing Equipment of Electrical and Electronic Products", and JJG190-89 "Trial Calibration Regulations for Electric Vibration Test Stand System" issued and implemented by the State Administration of Technical Supervision. These verification regulations are also an important basis for selecting environmental and reliability testing equipment. Testing equipment that does not meet the requirements of these verification regulations is not allowed to be put into use. 2、 Basic principles for equipment selection The selection of environmental and reliability testing equipment should follow the following five basic principles: 1. Reproducibility of environmental conditions It is impossible to fully and accurately reproduce the environmental conditions that exist in nature in the laboratory. However, within a certain tolerance range, people can accurately and approximately simulate the external environmental conditions that engineering products undergo during use, storage, transportation, and other processes. This passage can be summarized in engineering language as follows: "The environmental conditions (including platform environment) created by the testing equipment around the tested product should meet the requirements of the environmental conditions and their tolerances specified in the product testing specifications. The temperature box used for military product testing should not only meet the requirements of the national military standards GJB150.3-86 and GJB150.4-86 for different uniformity and temperature control accuracy. Only in this way can the reproducibility of environmental conditions be ensured in environmental testing. 2. Repeatability of environmental conditions An environmental testing equipment may be used for multiple tests of the same type of product, and a tested engineering product may also be tested in different environmental testing equipment. In order to ensure the comparability of test results obtained for the same product under the same environmental testing conditions specified in the testing specifications, it is necessary to require the environmental conditions provided by the environmental testing equipment to be reproducible. This means that the stress levels (such as thermal stress, vibration stress, electrical stress, etc.) applied by environmental testing equipment to the tested product are consistent with the requirements of the same testing specification. The repeatability of environmental conditions provided by environmental testing equipment is guaranteed by the national metrological verification department after passing the verification according to the verification regulations formulated by the national technical supervision agency. Therefore, it is necessary to require environmental testing equipment to meet the requirements of various technical indicators and accuracy indicators in the calibration regulations, and to not exceed the time limit specified in the calibration cycle in terms of usage time. If a very common electric vibration table is used, in addition to meeting technical indicators such as excitation force, frequency range, and load capacity, it must also meet the requirements of precision indicators such as lateral vibration ratio, table acceleration uniformity, and harmonic distortion specified in the calibration regulations. Moreover, the service life after each calibration is two years, and after two years, it must be re calibrated and qualified before being put into use. 3. Measurability of environmental condition parameters The environmental conditions provided by any environmental testing equipment must be observable and controllable. This is not only to limit the environmental parameters within a certain tolerance range and ensure the reproducibility and repeatability of the test conditions, but also necessary for the safety of product testing, in order to prevent damage to the tested product caused by uncontrolled environmental conditions and unnecessary losses. At present, various experimental standards generally require that the accuracy of parameter testing should not be less than one-third of the allowable error under experimental conditions. 4. Exclusion of environmental testing conditions Every time an environmental or reliability test is conducted, there are strict regulations on the category, magnitude, and tolerance of environmental factors, and non test required environmental factors are excluded from penetrating into it, in order to provide a definite basis for judging and analyzing product failure and fault modes during or after the test. Therefore, it is required that environmental testing equipment not only provide the specified environmental conditions, but also not allow any other environmental stress interference to be added to the tested product. As defined in the verification regulations for electric vibration tables, the table leakage magnetic flux, acceleration signal-to-noise ratio, and total root mean square value ratio of in band and out of band acceleration. The accuracy indicators such as random signal verification and harmonic distortion are all established as verification items to ensure the uniqueness of environmental testing conditions. 5. Safety and reliability of experimental equipment Environmental testing, especially reliability testing, has a long testing cycle and sometimes targets high-value military products. During the testing process, testing personnel often need to operate, inspect or test around the site. Therefore, it is required that environmental testing equipment must have the characteristics of safe operation, convenient operation, reliable use, and long working life to ensure the normal progress of the testing itself. The various protection, alarm measures, and safety interlock devices of the testing equipment should be complete and reliable to ensure the safety and reliability of the testing personnel, the tested products, and the testing equipment itself. 3、 Selection of Temperature and Humidity Chamber 1. Selection of Capacity When placing the test product (components, assemblies, parts or whole machine) into a climate chamber for testing, in order to ensure that the atmosphere around the test product can meet the environmental testing conditions specified in the test specifications, the working dimensions of the climate chamber and the overall dimensions of the test product should follow the following regulations: a) The volume of the tested product (W × D × H) shall not exceed (20-35)% of the effective working space of the test chamber (20% is recommended). For products that generate heat during testing, it is recommended to use no more than 10%. b) The ratio of the windward cross-sectional area of the tested product to the total area of the test chamber on that section shall not exceed (35-50)% (35% is recommended). c) The distance between the outer surface of the tested product and the wall of the test chamber should be kept at least 100-150mm (recommended 150mm). The above three provisions are actually interdependent and unified. Taking a 1 cubic meter cube box as an example, an area ratio of 1: (0.35-0.5) is equivalent to a volume ratio of 1: (0.207-0.354). A distance of 100-150mm from the box wall is equivalent to a volume ratio of 1: (0.343-0.512). In summary, the working chamber volume of the climate environment test chamber should be at least 3-5 times the external volume of the tested product. The reasons for making such regulations are as follows: After the test piece is placed in the box, it occupies the smooth channel, and narrowing the channel will lead to an increase in airflow velocity. Accelerate the heat exchange between the airflow and the test piece. This is inconsistent with the reproduction of environmental conditions, as relevant standards stipulate that the air flow velocity around the test specimen in the test chamber should not exceed 1.7m/s for temperature environmental tests, in order to prevent the test specimen and the surrounding atmosphere from generating heat conduction that is not in line with reality. When unloaded, the average wind speed inside the test chamber is 0.6-0.8m/s, not exceeding 1m/s. When the space and area ratio specified in points a) and b) are met, the wind speed in the flow field may increase by (50-100)%, with an average maximum wind speed of (1-1.7) m/s. Meet the requirements specified in the standards. If the volume or windward cross-sectional area of the test piece is increased without restrictions during the experiment, the actual airflow speed during the test will exceed the maximum wind speed specified in the test standard, and the validity of the test results will be questioned. The accuracy indicators of environmental parameters in the working chamber of the climate chamber, such as temperature, humidity, salt spray settling rate, etc., are all measured under no-load conditions. Once the test piece is placed, it will have an impact on the uniformity of the environmental parameters in the working chamber of the test chamber. The larger the space occupied by the test piece, the more severe this impact will be. Experimental data shows that the temperature difference between the windward and leeward sides in the flow field can reach 3-8 ℃, and in severe cases, it can be as high as 10 ℃ or more. Therefore, it is necessary to meet the requirements of a] and b] as much as possible to ensure the uniformity of environmental parameters around the tested product. According to the principle of heat conduction, the temperature of the airflow near the box wall is usually 2-3 ℃ different from the temperature at the center of the flow field, and may even reach 5 ℃ at the upper and lower limits of high and low temperatures. The temperature of the box wall differs from the temperature of the flow field near the box wall by 2-3 ℃ (depending on the structure and material of the box wall). The greater the difference between the test temperature and the external atmospheric environment, the greater the temperature difference. Therefore, the space within a distance of 100-150mm from the box wall is unusable. 2. Selection of temperature range At present, the range of temperature test chambers abroad is generally -73 to+177 ℃, or -70 to+180 ℃. Most domestic manufacturers generally operate at -80 to+130 ℃, -60 to+130 ℃, -40 to+130 ℃, and there are also high temperatures up to 150 ℃. These temperature ranges can usually meet the temperature testing needs of the vast majority of military and civilian products in China. Unless there are special requirements, such as products installed near heat sources such as engines, the upper temperature limit should not be blindly increased. Because the higher the upper limit temperature, the greater the temperature difference between the inside and outside of the box, and the poorer the uniformity of the flow field inside the box. The smaller the available studio size. On the other hand, the higher the upper limit temperature value, the higher the heat resistance requirements for insulation materials (such as glass wool) in the interlayer of the box wall. The higher the requirement for the sealing of the box, the higher the production cost of the box. 3. Selection of humidity range The humidity indicators given by domestic and foreign environmental test chambers are mostly 20-98% RH or 30-98% RH. If the humid heat test chamber does not have a dehumidification system, the humidity range is 60-98%. This type of test chamber can only perform high humidity tests, but its price is much lower. It is worth noting that the corresponding temperature range or minimum dew point temperature should be indicated after the humidity index. Because relative humidity is directly related to temperature, for the same absolute humidity, the higher the temperature, the lower the relative humidity. For example, if the absolute humidity is 5g/Kg (referring to 5g of water vapor in 1kg of dry air), when the temperature is 29 ℃, the relative humidity is 20% RH, and when the temperature is 6 ℃, the relative humidity is 90% RH. When the temperature drops below 4 ℃ and the relative humidity exceeds 100%, condensation will occur inside the box. To achieve high temperature and high humidity, simply spray steam or atomized water droplets into the air of the box for humidification. Low temperature and humidity are relatively difficult to control because the absolute humidity at this time is very low, sometimes much lower than the absolute humidity in the atmosphere. It is necessary to dehumidify the air flowing inside the box to make it dry. At present, the vast majority of temperature and humidity chambers both domestically and internationally adopt the principle of refrigeration and dehumidification, which involves adding a set of refrigeration light pipes to the air conditioning room of the chamber. When humid air passes through a cold pipe, its relative humidity will reach 100% RH, as the air saturates and condenses on the light pipe, making the air drier. This dehumidification method theoretically can reach dew point temperatures below zero degrees, but when the surface temperature of the cold spot reaches 0 ℃, the water droplets condensed on the surface of the light pipe will freeze, affecting the heat exchange on the surface of the light pipe and reducing the dehumidification capacity. Also, because the box cannot be completely sealed, humid air from the atmosphere will seep into the box, causing the dew point temperature to rise. On the other hand, the moist air flowing between the light tubes only reaches saturation at the moment of contact with the light tubes (cold spots) and releases water vapor, so this dehumidification method is difficult to keep the dew point temperature inside the box below 0 ℃. The actual minimum dew point temperature achieved is 5-7 ℃. A dew point temperature of 5 ℃ is equivalent to an absolute moisture content of 0.0055g/Kg, corresponding to a relative humidity of 20% RH at a temperature of 30 ℃. If a temperature of 20 ℃ and a relative humidity of 20% RH are required, with a dew point temperature of -3 ℃, it is difficult to use refrigeration for dehumidification, and an air drying system must be selected to achieve it. 4. Selection of control mode There are two types of temperature and humidity test chambers: constant test chamber and alternating test chamber. The ordinary high and low temperature test chamber generally refers to a constant high and low temperature test chamber, which is controlled by setting a target temperature and has the ability to automatically maintain a constant temperature to the target temperature point. The control method of the constant temperature and humidity test chamber is also similar, setting a target temperature and humidity point, and the test chamber has the ability to automatically maintain a constant temperature to the target temperature and humidity point. The high and low temperature alternating test chamber has one or more programs for setting high and low temperature changes and cycles. The test chamber has the ability to complete the test process according to the preset curve, and can accurately control the heating and cooling rates within the maximum heating and cooling rate capability range, that is, the heating and cooling rates can be controlled according to the slope of the set curve. Similarly, the high and low temperature alternating humidity test chamber also has preset temperature and humidity curves, and the ability to control them according to the preset. Of course, alternating test chambers have the function of constant test chambers, but the manufacturing cost of alternating test chambers is relatively high because they need to be equipped with curve automatic recording devices, program controllers, and solve problems such as turning on the refrigeration machine when the temperature in the working room is high. Therefore, the price of alternating test chambers is generally more than 20% higher than that of constant test chambers. Therefore, we should take the need for experimental methods as the starting point and choose a constant test chamber or an alternating test chamber. 5. Selection of variable temperature rate Ordinary high and low temperature test chambers do not have a cooling rate indicator, and the time from the ambient temperature to the nominal lowest temperature is generally 90-120 minutes. The high and low temperature alternating test chamber, as well as the high and low temperature alternating wet heat test chamber, both have temperature change speed requirements. The temperature change speed is generally required to be 1 ℃/min, and the speed can be adjusted within this speed range. The rapid temperature change test chamber has a fast temperature change rate, with heating and cooling rates ranging from 3 ℃/min to 15 ℃/min. In certain temperature ranges, the heating and cooling rates can even reach over 30 ℃/min. The temperature range of various specifications and speeds of rapid temperature change test chambers is generally the same, that is, -60 to+130 ℃. However, the temperature range for assessing the cooling rate is not the same. According to different test requirements, the temperature range of rapid temperature change test chambers is -55 to+80 ℃, while others are -40 to+80 ℃. There are two methods for determining the temperature change rate of the rapid temperature change test chamber: one is the average temperature rise and fall rate throughout the entire process, and the other is the linear temperature rise and fall rate (actually the average speed every 5 minutes). The average speed throughout the entire process refers to the ratio of the difference between the highest and lowest temperatures within the temperature range of the test chamber to the time. At present, the technical parameters of temperature change rate provided by various environmental testing equipment manufacturers abroad refer to the average rate throughout the entire process. The linear temperature rise and fall rate refers to the guaranteed temperature change rate within any 5-minute time period. In fact, for the rapid temperature change test chamber, the most difficult and critical stage to ensure the linear temperature rise and fall speed is the cooling rate that the test chamber can achieve during the last 5 minutes of the cooling period. From a certain perspective, the linear heating and cooling speed (average speed every 5 minutes) is more scientific. Therefore, it is best for the experimental equipment to have two parameters: the average temperature rise and fall speed throughout the entire process and the linear temperature rise and fall speed (average speed every 5 minutes). Generally speaking, the linear heating and cooling speed (average speed every 5 minutes) is half of the average heating and cooling speed throughout the entire process. 6. Wind speed According to relevant standards, the wind speed inside the temperature and humidity chamber during environmental testing should be less than 1.7m/s. For the test itself, the lower the wind speed, the better. If the wind speed is too high, it will accelerate the heat exchange between the surface of the test piece and the airflow inside the chamber, which is not conducive to the authenticity of the test. But in order to ensure uniformity within the testing chamber, it is necessary to have circulating air inside the testing chamber. However, for rapid temperature change test chambers and comprehensive environmental test chambers with multiple factors such as temperature, humidity, and vibration, in order to pursue the rate of temperature change, it is necessary to accelerate the flow velocity of the circulating airflow inside the chamber, usually at a speed of 2-3m/s. Therefore, the wind speed limit varies for different usage purposes. 7. Temperature fluctuation Temperature fluctuation is a relatively easy parameter to implement, and most test chambers produced by environmental testing equipment manufacturers can actually control temperature fluctuations within a range of ± 0.3 ℃. 8. Uniformity of temperature field In order to simulate the actual environmental conditions that products experience in nature more accurately, it is necessary to ensure that the surrounding area of the tested product is under the same temperature environment conditions during environmental testing. Therefore, it is necessary to limit the temperature gradient and temperature fluctuation inside the test chamber. In the General Principles of Environmental Test Methods for Military Equipment (GJB150.1-86) of the National Military Standard, it is clearly stipulated that "the temperature of the measurement system near the test sample should be within ± 2 ℃ of the test temperature, and its temperature should not exceed 1 ℃/m or the total maximum value should be 2.2 ℃ (when the test sample is not working). 9. Precision control of humidity The humidity measurement in the environmental testing chamber mostly adopts the dry wet bulb method. The manufacturing standard GB10586 for environmental testing equipment requires that the relative humidity deviation should be within ± 23% RH. To meet the requirements of humidity control accuracy, the temperature control accuracy of the humidity test chamber is relatively high, and the temperature fluctuation is generally less than ± 0.2 ℃. Otherwise, it will be difficult to meet the requirements for humidity control accuracy. 10. Cooling method selection If the test chamber is equipped with a refrigeration system, the refrigeration system needs to be cooled. There are two forms of test chambers: air-cooled and water-cooled.   Forced air cooling     Water-cooling Working conditions The equipment is easy to install, only need to power on. The ambient temperature should be lower than 28℃. If the ambient temperature is higher than 28℃, it has a certain impact on the refrigeration effect (preferably with air conditioning), the circulating cooling water system should be configured. Heat exchange effect  Poor (relative to the water-cooling mode)  Stable, good  Noise Large (relative to the water-cooling mode)    Less
    إقرأ المزيد
  • The walk-in high and low temperature (humid and hot) laboratory also needs maintenance The walk-in high and low temperature (humid and hot) laboratory also needs maintenance
    Oct 15, 2024
    The walk-in high and low temperature (humid and hot) laboratory also needs maintenance Reminder: Remember to maintain the walk-in high and low temperature (humid and hot) laboratory as well! 1. The temperature and humidity testing system of the walk-in high and low temperature (humid and hot) laboratory must be operated and maintained by a dedicated person. Strictly follow the operating procedures of the system and avoid others from operating the system illegally. 2. Long term shutdown of the walk-in high and low temperature (humid and hot) laboratory can affect the effective service life of the system. Therefore, the system should be turned on and operated at least once every 10 days; Do not repeatedly stop the system in a short period of time. The number of starts per hour should be less than 5 times, and the time interval between each start stop should not be less than 3 times; Do not open the door of the walk-in temperature and humidity testing system at low temperatures to prevent damage to the door sealing tape. 3. A system usage file should be established to facilitate system maintenance and repair. The use of archives should record the start and end time (date) of each system operation, the type of experiment, and the ambient temperature; When the system malfunctions, provide a detailed description of the fault phenomenon as much as possible; The maintenance and repair of the system should also be recorded in as much detail as possible. 4. Conduct a monthly main power switch (leakage circuit breaker) operation test to ensure that the switch is used as a leakage protector while meeting the load capacity. The specific steps are as follows: first, please confirm that the main power switch is turned to "ON", which means the system is powered on, and then press the test button. If the switch lever of the residual current circuit breaker falls down, this function is normal. 5. The main box of the walk-in temperature and humidity testing system should be protected during use and should not be subjected to strong impacts from sharp or blunt objects. 6. To ensure the normal and clean supply of cooling water, the cooling water filter of the refrigeration unit should be cleaned every 30 days. If the local air quality is poor and the dust content in the air is high, the cooling water tower reservoir should generally be cleaned every 7 days. 7. The leakage, overload, and short-circuit protection characteristics of the residual current switch are set by Lab Companion manufacturer and cannot be adjusted arbitrarily during use to avoid affecting performance; After the leakage switch is disconnected due to a short circuit, the contacts need to be checked. If the main contacts are severely burned or have pits, maintenance is required. 8. The test products placed in the walk-in temperature and humidity testing system should be kept at a certain distance from the suction and exhaust ports of the air conditioning channel to avoid obstructing air circulation. 9. Overtemperature protector action test. Set the temperature of the over temperature protector to be lower than the temperature of the box. If there is an E0.0 alarm and buzzing sound, it indicates that its function is normal. After completing the above experiment, the temperature protection setting should be reset appropriately, otherwise it may cause inappropriate termination. 10. Once a year, use a vacuum cleaner to clean and remove dust from the distribution room and water circuit room. Once a month, use a dry cloth to clean the accumulated water in the water tray of the refrigeration unit.
    إقرأ المزيد
  • EC-85MHPM-W ، خزان درجة حرارة ورطوبة ثابت للحمل العالي (800 لتر) EC-85MHPM-W ، خزان درجة حرارة ورطوبة ثابت للحمل العالي (800 لتر)
    Nov 13, 2014
    EC-85MHPM-W، خزان درجة حرارة ورطوبة ثابت ذو حمولة عالية (800 لتر)مشروعيكتبمسلسلMHPM-Wوظيفةوضع درجة الحرارة والرطوبةطريقة الكرة الرطبةنطاق درجة الحرارة-40 ~ + 100 درجة مئويةنطاق الرطوبة20 ~ 98% رطوبة نسبية(وفقا للطور الانفصالي 3 عناصر)التغيرات في درجة الحرارة والرطوبة± 0.3 درجة مئوية / ± 2.5% رطوبة نسبيةتوزيع درجة الحرارة والرطوبة± 0.5 درجة مئوية / ±5.0% رطوبة نسبيةتنخفض درجة الحرارة الوقت+20 ~ -40 درجة مئوية75 يورووقت ارتفاع درجة الحرارة-40 ~ + 100 درجة مئوية50 دولارا أمريكياتم اختبار الحجم الداخلي للرحم800Lطريقة قياس بوصة الغرفة (العرض والعمق والارتفاع)1000 مم × 800 مم × 1000 ممطريقة بوصة المنتج (العرض والعمق والارتفاع)1400 مم × 1190 مم × 1795 مماصنع المادةالزي الخارجيلوحة تحكم غرفة الاختبارغرفة الآلةلوح فولاذي بارد، لوح فولاذي بارد باللون البيج(جدول الألوان 2.5Y8/2)داخللوح من الفولاذ المقاوم للصدأ (SUS304,2B مصقول)مادة حرارية مكسورةاختبار الرحمراتنجات صناعية صلبة―بابقطن رغوي من الراتنج الصناعي الصلب، قطن زجاجيمشروعيكتبمسلسلMHPM-Wإزالة التبريد، جهاز مبلل طريقة التبريد وضع انكماش القسم الميكانيكي وسط التبريدR404Aيمكن للمرء أن يتقلص الآلةالناتج (عدد الموظفين)1.5 كيلو واط (1)التبريد ومزيل الرطوبةنوع المشتت الحراري المختلط متعدد القنواتالمكثفحوض رادياتير مختلط متعدد القنوات (تبريد الهواء)مسعراستمارةسخان سبائك النيكل والكروم المقاوم للحرارةمقدار3.5 كيلو واط مرطب استمارةتوليد البخارمقدار1.8 كيلووات×2منفاخاستمارةحوض رادياتير مختلط متعدد القنوات (تبريد الهواء)سعة المحرك40 واطوحدة تغذية المياهاسطوانة إمداد المياه طريقة إمداد المياهنوعية المياهالماء النقي * إمدادات المياه التلقائية((يُرجى الرجوع إلى مصدر إمداد المياه التلقائي.))مقدار نوع الجاذبية قرص مرطب نوع الجاذبية المراقب المالينطاق ضبط درجة الحرارة-42.0 ~ + 102.0 درجة مئويةنطاق ضبط الرطوبة0 ~ 98% رطوبة نسبية (درجة حرارة اللمبة الجافة 10 ~ 85 درجة مئوية)النطاق الزمني المحدد0 ~ 999 وقت 59 دقيقة (نوع إعداد البرنامج) 0 ~ 20000 وقت 59 دقيقة (نوع القيمة)ضبط طاقة التحللدرجة الحرارة 0.1 درجة مئوية، الرطوبة 1% رطوبة نسبية لمدة دقيقة واحدةتشير إلى الدقةدرجة الحرارة ± 0.8 درجة مئوية (TP)، الرطوبة ± 1% رطوبة نسبية (TP)، الوقت ± 100 جزء في المليوننوع الإجازةالقيمة أو البرنامجرقم المرحلة20 مرحلة / 1 برنامجعدد الإجراءاتالحد الأقصى لعدد برامج القوة الواردة (RAM) هو 32 برنامجًاالحد الأقصى لعدد برامج ROM الداخلية هو 13 برنامجًارقم الرحلة ذهابا وإيابا 98 مرة كحد أقصى أو غير محدودعدد مرات تكرار الرحلة ذهابًا وإيابًاالحد الأقصى 3 ثقيلإزاحة النهايةحزب العمال 100Ω (عند 0 ℃)، الصف B( JIS C 1604-1997)إجراء التحكمعند تقسيم الإجراء PIDوظيفة داخليةوظيفة التسليم المبكر، وظيفة الاستعداد، تحديد وظيفة صيانة القيمة، وظيفة حماية انقطاع التيار الكهربائي،وظيفة اختيار عمل الطاقة، وظيفة الصيانة، وظيفة النقل ذهابًا وإيابًا،وظيفة تسليم الوقت، وظيفة إخراج إشارة الوقت، وظيفة منع الإفراط في التبريد الزائد،وظيفة التمثيل غير الطبيعي، وظيفة إخراج التنبيه الخارجي، إعداد وظيفة تمثيل النموذج،وظيفة اختيار نوع النقل، يمثل وقت الحساب الوظيفة، وظيفة مصباح الفتحةمشروعيكتبمسلسلMHPM-Wلوحة التحكمآلة المعداتلوحة التشغيل LCD (اكتب لوحة الاتصال)،يمثل المصباح (الطاقة، النقل، غير الطبيعي)، محطة إمداد الطاقة الاختبارية، محطة الإنذار الخارجية،محطة إخراج إشارة الوقت، موصل سلك الطاقة جهاز الحماية دورة التبريدجهاز حماية الزائد، جهاز حجب عاليةمسعرجهاز حماية من ارتفاع درجة الحرارة، مصهر درجة الحرارةمرطب جهاز منع حرق الهواء، منظم مستوى الماء بقرص الترطيبمنفاخجهاز حماية الزائدلوحة التحكمقاطع التسرب لإمدادات الطاقة، الصمامات (للسخان، المرطب)،المصهر (لحلقة التشغيل)، جهاز الحماية من ارتفاع درجة الحرارة (للاختبار)،جهاز منع التبريد الزائد لارتفاع درجة الحرارة (مادة الاختبار، في الحواسيب الصغيرة)المنتجات الثانوية (مجموعات)جهاز استقبال المنزل (4)، لوحة المنزل (2)، فتيل الكرة الرطبة (15)، دليل التشغيل (1)منتجات المعداتالبرانيةزجاج البورسليكات الصلب  800 مم × 800 مم2فتحة الكابلحجم الحفرة 50 ملم1الحوض الصغير داخل المصباحكرة ساخنة بيضاء AC100V 15W2عجلة 4التعديل الأفقي 4خصائص الفيروس الكهربائيمصدر التيار المتردد  ثلاثي الطور 380 فولت 50 هرتزالحد الأقصى للحمل الحالي25 أقدرة قاطع التسرب لإمدادات الطاقة50 أالتيار الحسي  30 مللي أمبيرسمك توزيع الطاقة14 مللي متر2خرطوم عازل مطاطيخشونة سلك التأريض
    إقرأ المزيد
  • نصائح الصيانة اليومية لغرف اختبار درجات الحرارة العالية والمنخفضة وغرف اختبار درجات الحرارة العالية والمنخفضة بالتناوب نصائح الصيانة اليومية لغرف اختبار درجات الحرارة العالية والمنخفضة وغرف اختبار درجات الحرارة العالية والمنخفضة بالتناوب
    Oct 09, 2024
    نصائح الصيانة اليومية لغرف اختبار درجات الحرارة العالية والمنخفضة وغرف الاختبار ذات درجات الحرارة العالية والمنخفضة بالتناوب1. غرف اختبار درجات الحرارة العالية والمنخفضة تكون مرتفعة نسبيًا بشكل عام، ونوصي بوضعها في بيئة ذات درجة حرارة معتدلة نسبيًا. قيمة درجة حرارة تجربتنا هي 8 درجه مئوية ~ 23 درجه مئوية. أما بالنسبة للمختبرات التي لا تتوافر فيها هذه الحالة فيجب تجهيز مكيفات أو أبراج تبريد مناسبة.2. من الضروري الالتزام بالإدارة المهنية من قبل موظفين متخصصين. يجب على الوحدات ذات الشروط إرسال موظفين متخصصين بشكل دوري إلى مصنع المورد للتدريب والتعلم، من أجل اكتساب المزيد من الخبرة المهنية والقدرة على صيانة وإصلاح أدوات Hongzhan.3. قم بتنظيف المكثف بانتظام كل 3 أشهر: بالنسبة للضواغط التي تستخدم التبريد بتبريد الهواء، يجب فحص مروحة المكثف بانتظام ويجب تنظيف المكثف وإزالة الغبار عنه لضمان التهوية الجيدة وأداء نقل الحرارة؛ بالنسبة للضواغط التي تستخدم التبريد المبرد بالماء، بالإضافة إلى ضمان ضغط المياه الداخلة ودرجة حرارتها، فمن الضروري أيضًا ضمان معدل التدفق المقابل. يعد التنظيف المنتظم وإزالة الترسبات الكلسية للجزء الداخلي للمكثف ضروريًا أيضًا للحصول على أداء نقل الحرارة المستمر.4. تنظيف المبخر بانتظام: نظرًا لاختلاف مستويات النظافة لعينات الاختبار، فإن الكثير من الجزيئات الصغيرة مثل الغبار سوف تتراكم على المبخر تحت دوران الهواء القسري، ويجب تنظيفها بانتظام.5. تنظيف وموازنة شفرات الهواء الدائرية ومراوح المكثف: كما هو الحال مع مبخرات التنظيف، نظرًا لبيئات العمل المختلفة لغرفة الاختبار، قد تتراكم العديد من الجزيئات الصغيرة مثل الغبار على شفرات الهواء الدائرية ومراوح المكثف، ويجب تنظيفها. بانتظام.6. تنظيف الممر المائي وجهاز الترطيب: إذا لم يكن الممر المائي سلسًا وكان جهاز الترطيب عبارة عن قشور، فمن السهل على جهاز الترطيب أن يجف ويحترق، مما قد يؤدي إلى تلف جهاز الترطيب. ولذلك، فمن الضروري تنظيف الممر المائي والمرطب بانتظام.7. بعد كل تجربة، اضبط درجة الحرارة بالقرب من درجة الحرارة المحيطة، واعمل لمدة 30 دقيقة تقريبًا، ثم قم بقطع الطاقة وتنظيف الجدار الداخلي للورشة.إذا كانت المعدات بحاجة إلى النقل، فمن الأفضل القيام بذلك تحت إشراف الموظفين الفنيين من شركة Hongzhan لتجنب حدوث أي ضرر أو تلف غير ضروري للمعدات.عندما لا يكون المنتج قيد الاستخدام لفترة طويلة من الزمن، يجب تشغيله بانتظام كل نصف شهر، ويجب ألا تقل الطاقة في الوقت المحدد عن ساعة واحدة.10. مبدأ الصيانة:نظرًا لحقيقة أن غرف اختبار درجات الحرارة العالية والمنخفضة تتكون بشكل أساسي من الأنظمة الكهربائية والتبريد والميكانيكية، فإنه بمجرد وجود مشكلة في المعدات، يجب إجراء فحص وتحليل شامل لنظام المعدات بأكمله.بشكل عام، يمكن أن تبدأ عملية التحليل والحكم بـ "خارجي" ثم "داخلي"، أي أنه بعد استبعاد العوامل الخارجية، يمكن أن تتحلل المعدات بشكل منهجي بناءً على ظاهرة الخطأ. ومن ثم، يمكن تحليل النظام والحكم عليه بشكل شامل. وبدلاً من ذلك، يمكن استخدام طريقة التفكير العكسي للعثور على سبب العطل: أولاً، تحقق مما إذا كانت هناك مشكلة في النظام الكهربائي وفقًا لمخطط الأسلاك الكهربائية، وأخيرًا تحقق مما إذا كانت هناك مشكلة في نظام التبريد. قبل فهم سبب الخلل، ليس من المستحسن تفكيك المكونات أو استبدالها بشكل أعمى لتجنب حدوث مشاكل غير ضرورية.
    إقرأ المزيد
  • استقرت أول محطة اختبار تثليج البيئة الطبيعية في الصين ، تم بناؤها بشكل مشترك من قبل جامعة تشونغتشينغ ومكتب الطاقة الكهربائية Huaihua ، في جبل Xuefeng! استقرت أول محطة اختبار تثليج البيئة الطبيعية في الصين ، تم بناؤها بشكل مشترك من قبل جامعة تشونغتشينغ ومكتب الطاقة الكهربائية Huaihua ، في جبل Xuefeng!
    Jan 09, 2010
    استقرت أول محطة اختبار تجميد البيئة الطبيعية في الصين، والتي تم بناؤها بشكل مشترك من قبل جامعة Chongqing ومكتب Huaihua للطاقة الكهربائية، في جبل Xuefeng!في 16 يناير، عُقدت في هوايهوا ندوة تبادل تكنولوجيا اختبار الغطاء الجليدي العازل "محطة اختبار الغطاء الجليدي الطبيعي شيوفنغشان"، التي نظمتها بشكل مشترك جامعة تشونغتشينغ ومعهد هونان هوايهوا لتصميم الطاقة الكهربائية. اجتمع خبراء في خطوط النقل والتوزيع وتكنولوجيا العزل من جامعات معروفة في جميع أنحاء البلاد، بالإضافة إلى خبراء كهربائيين من شركة NGK اليابانية، للاحتفال بالانتهاء الرسمي من محطة اختبار الغطاء الجليدي الطبيعي الوحيدة في العالم والأولى في الصين في هوايهوا. هونان، ومناقشة المسائل البحثية المتابعة.في الاجتماع، أعرب البروفيسور جيانغ شينغليانغ، مشرف الدكتوراه في جامعة تشونغتشينغ، في البداية عن امتنانه لمكتب الطاقة الكهربائية في هوايهوا والوحدات المختلفة لنظام الطاقة لدعمهم القوي ومساعدتهم في التصميم الأساسي وبناء القاعدة التجريبية. استمع الخبراء الحاضرون إلى تقرير البروفيسور المشارك تشانغ تشي جين حول بناء محطة اختبار الغطاء الجليدي الطبيعي في شيوفنغشان واختبار الغطاء الجليدي لعام 2009، وشاركوا نتائج مراقبة الجليد والأبحاث في قاعدة الاختبار طوال عام 2009، وأجروا مناقشات وأبحاث متعمقة على المشاكل القائمة. وبعد الاجتماع، ذهب الخبراء أيضًا إلى "محطة اختبار الغطاء الجليدي الطبيعي في شيوفنغشان" لإجراء تحقيق في الموقع، وأعرب الممثلون عن تأكيدهم على اختيار الموقع وبناء محطة الاختبار.أوضح البروفيسور جيانغ شينغليانغ أنه منذ كارثة الجليد عام 2008، ومن أجل منع عدد كبير من انقطاع الخطوط وانهيار الأبراج وحوادث ومضات الجليد الناجمة عن الجليد الشديد، وللحفاظ على التشغيل الآمن والمستقر لشبكة الطاقة، قامت وزارة الطاقة أدرجت العلوم والتكنولوجيا في الصين تكنولوجيا تجميد الشبكات وحمايتها كأحد موضوعات البحث المهمة في الخطة الوطنية الرئيسية للبحث والتطوير (خطة 973). بدعم من مشاريع مثل "الغطاء الجليدي، وإزالة الجليد، وآليات ذوبان خطوط النقل" من قبل شركة State Grid Corporation الصينية، أجرى فريق بحث البروفيسور جيانغ شينغليانغ تحقيقًا شاملاً لظروف الغطاء الجليدي النموذجي في الصين، وقام بتحليل ومقارنة الغطاء الجليدي الظواهر والأرصاد الجوية الدقيقة في ليوبانشوي وقويتشو وجبال تشينلينغ وشنشي وجينغمن وسيتشوان ولوشان وجيانغشي. واستنادًا إلى تمثيل الغطاء الجليدي ومدته وظروف نقله، فقد تقرر إنشاء "قاعدة اختبار الغطاء الجليدي الطبيعي" في شيوفنغشان بمقاطعة هونان. كان من المعتقد أن الظروف الطبيعية لـ Pingshantang في Xuefengshan والقوة الفنية لمعهد Huaihua للتصميم تلبي متطلبات بناء قواعد اختبار الغطاء الجليدي الطبيعي. وأخيراً تم تحديد اختيار الموقع وشريك التعاون.في عام 2009، قام البروفيسور جيانغ شينغليانغ، والأستاذ المشارك تشانغ تشي جين، والدكتور هو جيان لين، من بين الأعضاء الرئيسيين الآخرين في مجموعة البحث، بقيادة أكثر من عشرة طلاب دراسات عليا من قسم الجهد العالي وتكنولوجيا العزل في جامعة تشونغتشينغ للتغلب على الصعوبات المختلفة في العمل والحياة في ظل الظروف الطبيعية القاسية. لقد عملوا مع معهد Huaihua Bureau Design Institute لبناء قاعدة تجريبية طبيعية أثناء إجراء البحوث التجريبية. في السنة الأولى من التجربة، تمت دراسة عمليات التجميد والذوبان وإزالة الجليد لستة مواصفات نموذجية للموصلات المستخدمة عادة في خطوط نقل الجهد العالي، والجهد العالي جدًا، والجهد العالي جدًا. تمت ملاحظة ومقارنة عمليات التثليج لأنواع مختلفة من العوازل. تم التحقيق تجريبيًا في تدابير تقنية متعددة لمنع تثليج الموصل، مثل الطلاءات الميكانيكية والكارهة للماء، بالإضافة إلى الطلاءات لمنع تثليج العازل والاختلافات في ترتيبات تثليج العازل. تم تحليل عملية الالتواء وآلية تثليج الموصل، وتم تحليل تغيرات التوتر وتغير حمل الرياح الجليدية بعد تثليج الموصل. بالإضافة إلى ذلك، تم إجراء اختبارات تجمد التيار المتردد والتيار المستمر في البيئات الطبيعية. تم تجميع كمية كبيرة من البيانات التجريبية الرئيسية للتغلب على المشكلة العالمية المتمثلة في تجميد شبكة الطاقة، وتم إجراء العديد من الدراسات والاستكشافات الفعالة.صرح توشيوكي ناكاجيما، كبير المهندسين بقسم الطاقة الكهربائية بشركة NGK في اليابان، في مقابلة مع الصحفيين أثناء تفقده لمحطة اختبار الغطاء الجليدي الطبيعي في شيوفنغشان أنه شارك في أبحاث حول الغطاء الجليدي لشبكة الطاقة في الولايات المتحدة من أجل 10 سنوات. على الرغم من أن الخبراء الدوليين قد أجروا أبحاثًا طويلة المدى حول الغطاء الجليدي لشبكة الطاقة في ظل ظروف المحاكاة الاصطناعية المختبرية، إلا أنهم يعتقدون بالإجماع أن هناك خطأً كبيرًا بين شكل الغطاء الجليدي في بيئة المحاكاة الاصطناعية والوضع الفعلي في البيئة الطبيعية. إن أول محطة اختبار للغطاء الجليدي الطبيعي تم بناؤها في Xuefengshan سوف تعزز بشكل كبير عملية البحث عن الغطاء الجليدي وآليات ذوبان خطوط النقل والقدرة على مكافحة الجليد لشبكات الطاقة في الصين وعلى المستوى الدولي. ويتمنى أن يحصل نظراؤه الصينيون قريبا على أساس الغطاء الجليدي على خطوط النقل في البيئات الطبيعية. تسد البيانات الفجوة في الأبحاث الدولية في هذا المجال، وتتغلب على التحدي العالمي المتمثل في آلية تثليج شبكة الطاقة وتكنولوجيا مكافحة التثليج في أسرع وقت ممكن.صرح Zhang Jiwu، رئيس معهد التصميم لمكتب Huaihua للطاقة الكهربائية، أنه بدعم قوي من السكرتير Liang Liqing من لجنة حزب مكتب Huaihua للطاقة الكهربائية، تم بناء محطة اختبار الغطاء الجليدي الطبيعي Xuefengshan بالتعاون مع جامعة Chongqing. من ناحية، يمكنها تقديم مساهمتها الخاصة في البحث حول تحسين مقاومة الجليد لشبكة الطاقة وتعكس إحساس الشركة بالمسؤولية الاجتماعية؛ ومن ناحية أخرى، يمكنها أيضًا تعزيز قوتها التكنولوجية وسمعة الشركة من خلال التعاون والتبادل، وتحسين قدرتها التنافسية الخارجية، وتحقيق وضع مربح للجانبين. إنه نموذج للتعاون "الأبحاث الجامعية الصناعية" بين الشركات ومؤسسات التعليم العالي. (شو دايسونج وتشانغ دمينغ)مصدر المعلومات: شركة هونان للطاقة الكهربائيةلدى Lab Companion مؤسسة بحثية متخصصة في تطوير معدات الاختبار البيئي، مع أساليب بحث ومختبرات ناضجة للاختبار البيئي. لقد جمعت مجموعة من المواهب الممتازة والخبراء المعروفين في الصناعة، ويقود فريق البحث والتطوير القوي اتجاه تطوير تكنولوجيا الاختبار البيئي المحلي. في الوقت الحاضر، تتمتع الشركة بحقوق ملكية فكرية مستقلة في معدات الاختبار البيئي، ومعدات اختبار الموثوقية، وغرف اختبار درجات الحرارة العالية والمنخفضة، وغرف اختبار الرطوبة ذات درجات الحرارة العالية والمنخفضة، وغرف اختبار درجة الحرارة والرطوبة الثابتة، وغرف اختبار التغير السريع في درجات الحرارة، والباردة والساخنة. غرف اختبار الصدمات، ثلاث غرف اختبار شاملة، غرف اختبار درجات الحرارة العالية والمنخفضة والضغط المنخفض، غرف اختبار الإشعاع الشمسي، الأفران الصناعية، غرف اختبار الصدمات الباردة والساخنة، غرف اختبار درجة الحرارة والرطوبة الثابتة، غرف اختبار فحص الإجهاد البيئي، غرف اختبار درجة الحرارة والرطوبة الثابتة، غرف اختبار تأثير درجات الحرارة العالية والمنخفضة، آلات اختبار درجة الحرارة والرطوبة الثابتة، غرف اختبار درجة الحرارة والرطوبة الثابتة، غرف اختبار الإشعاع الشمسي، غرف اختبار الرطوبة ذات درجات الحرارة العالية والمنخفضة، غرف التحكم في درجة الحرارة والرطوبة ، آلات اختبار الشيخوخة المعجلة بالأشعة فوق البنفسجية، آلات اختبار التجوية المعجلة بالأشعة فوق البنفسجية، غرف الاختبار المباشرة، غرف الاختبار البيئي. الغرفة، ومختبر درجات الحرارة العالية والمنخفضة، وغرفة اختبار التحكم في درجة الحرارة والرطوبة، وغرفة اختبار مقاومة الطقس للأشعة فوق البنفسجية، واختبار الشيخوخة بالأشعة فوق البنفسجية، ومعدات اختبار البيئة المناخية والمنتجات المخصصة، بما في ذلك درجة حرارة عالية ومنخفضة وغرف اختبار الضغط المنخفض، غرف اختبار درجات الحرارة السريعة للدراجات، غرف اختبار درجة الحرارة والرطوبة الثابتة، غرف اختبار درجة الحرارة والرطوبة العالية والمنخفضة، أفران دقيقة، غرف اختبار درجة الحرارة والرطوبة الثابتة القابلة للبرمجة، آلات اختبار درجة الحرارة والرطوبة الثابتة القابلة للبرمجة، غرف اختبار تقادم مصباح زينون، غرف اختبار الرطوبة ودرجة الحرارة الثابتة القابلة للبرمجة، تعتبر غرف اختبار الرطوبة المتناوبة ذات درجة الحرارة المنخفضة، وغرف اختبار درجة الحرارة والرطوبة الثابتة، وغرف اختبار الرطوبة ذات درجات الحرارة العالية والمنخفضة، وغرف اختبار المطر ذات سرعة الرياح العالية، في طليعة المعايير المحلية والدولية. نرحب بالعملاء الجدد والقدامى للاتصال بنا للاستفسار. سنكون ملتزمين بخدمتك!
    إقرأ المزيد

اترك رسالة

اترك رسالة
إذا كنت مهتما بمنتجاتنا وتريد معرفة المزيد من التفاصيل ، فالرجاء ترك رسالة هنا ، وسوف نقوم بالرد عليك في أقرب وقت ممكن.
إرسال

وطن

منتجات

واتس اب

اتصل بنا